ADV200-HC Manual
Page 16 of 55
26.05 BRAKE CONTROL
This function manages brake opening and closing.
Brake opening is subject to exceeding thresholds, differentiable in the 2 directions; current and speed
reference if the drive is configured in V/f or Flux Vector Open Loop mode, torque and speed reference if it is
configured in Flux Vector Close Loop mode.
The speed reference during brake opening equals ”FWD/REV OPEN Speed set” and remains the same until
the brake open command is given. During this phase the state monitor is “pre RUN”.
Brake closing is subject to exceeding the (speed) threshold, differentiable in the 2 directions. You can also
insert a delay time for disabling the drive after brake closing.
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
26.05.01
11026
FWD OPEN current thr
A
FLOAT 1
0
1000
R/W
Current threshold for brake opening, FWD
Set this parameter only in control mode V/f or FOC OL.
26.05.02
11028
FWD OPEN torque thr
%
FLOAT 0
0
200
R/W
Torque threshold for brake opening, FWD
Set this parameter only in control mode FOC CL.
26.05.03
11030
FWD OPEN speed thr
rpm
FLOAT 20
0
1000
R/W
Speed threshold for brake opening, FWD.
26.05.04
11036
FWD OPEN speed set
rpm
FLOAT 50
0
1000
R/W
Speed reference for brake opening, FWD.
26.05.05
11038
FWD CLOSE speed thr
rpm
FLOAT 100 1
1000
R/W
Speed threshold for brake closing, FWD