ADV200-HC Manual
Page 11 of 55
MENU
PAR
Description
UM
Type
Def
Min
Max
ACCESS
Reception of only the REV command (without FWD) generates the “JOYSTICK ERROR”
alarm”.
Digital Inputs
Direction
Statr
FWD
REV
FWD cmd src (IPA11152)
X
START FWD
REV cmd src (IPA11154)
X
X
START REV
If
“
Jstk Speed Type
”
is set as Digital, 2 digital inputs set via
“
Multi spd 1 src
”
and
“
Multi spd 2
src
”
let you choose 4 possible speed references (CMD SPEED \
…
) according to the following
table.
Digital Inputs
Speed
Speed 1
(IPA11004)
Speed 2
(IPA11006)
Speed 3
(IPA11010)
Speed 4
(IPA11054)
Multi spd 1 src
(IPA11156)
0
1
0
1
Multi spd 2 src
(IPA11158)
0
0
1
1
If
“
Jstk Speed Type
”
is set as Analog, the speed reference depends on the value of the analog
input selected via ANALOG INPUT\ Speed ref src.
The maximum value of the analog input matches the
“
Speed 1
”
parameter on the CMD SPEED
menu.
26.02.03
11062
Jstk speed type
*
ENUM
Digital
*
*
R/W
Input type for speed reference: digital or analog.
0 Digital = Speed reference depends on value set in CMD SPEED\Speed 1, Speed 2, Speed
3, Speed 4 parameters and on commands assigned to digital inputs set as DIGITAL
INPUT\\Multi speed 1 src and Multi speed 2 src
1 Analog =Speed reference depends on analog input set via ANALOG INPUT\ Speed ref src.
26.02.04
11064
Jstk zero position
*
BOOL Off
*
*
R/W
Enable check of joystick Zero position.
26.02.05
11074
Rotate inversion
*
BOOL Off
*
*
R/W
Reverse direction of movement of commands received.
26.02.06
11114
Brake
*
BOOL On
*
*
R/W
Enable brake management:
ON = Limits specified in the BRAKE CONTROL command will be used for brake opening
OFF =Only the delay settable in the
“
BRAKE CONTROL / OPEN delay
”
parameter will be
used for brake opening
26.02.07
11122
Brake fbk
*
ENUM None *
*
R/W
Setting brake feedback:
0 Norm Close = Normally closed when brake is ON (motor blocked)
1 Norm Open = Normally open when brake is ON (motor blocked)
2 None (brake feedback not sent to drive)
26.02.08 11142
Limit switch
*
ENUM None *
*
R/W
Enabling management of limit switches.
0 = Norm Close = Normally closed when position of controlled element does not exceed
Содержание ADV200 ASY