Carry out the following steps:
1.
Unscrew the snap ring (46) between the actuator and lantern.
2.
Secure drive (A) with a band wrench. Place the spanner onto the spanner
surface of the cleaning hood (11) and remove the drive
®
The valve insert has been removed from the actuator.
10.5.3 Disassembly of the valve insert.
Fig.11
Notice
The lantern and the shaft of the valve disc are delicate
components.
When the valve insert is withdrawn, the bearing washer (4) and the sealing
washer (3) can damage the shaft (16) of the double disc.
► Carefully remove the valve insert out of the lamp (9).
► Do not hit the threads of the cleaning hood (11) on the lamp.
Carry out the following steps:
1.
Pull the valve insert out of the lamp (9).
2.
Secure the valve disc on the borehole (15a) with a suitable tool. Place the
spanner on to the spanner flat (11a) of the cleaning hood (11) and undo the
valve disc.