Warning!
Spring tension in the valve
Danger of injury when detaching the clamp connection (43) as the released
spring pretension will suddenly lift the actuator.
► Therefore, release the spring tension before detaching the clamp
connections by pressurizing the actuator with compressed air at max. 8 bar.
Carry out the following steps:
1.
Remove the cleaning connection (30).
2.
Vent the valve at connection (L).
®
The valve discs (15/16) are raised.
3.
Remove the snap ring (43.1).
4.
Interrupt the compressed air supply to the connection (L).
5.
Pull off the control top (B) upwards.
®
Light-emitting diode A (green) will go out and light-emitting diode B will
flash yellow.
®
The valve insert has been removed.
10.5.2 Separating the valve from the drive
Fig.10
Notice
The piston rod and the shaft of the valve disc are delicate
components.
When unscrewing the actuator, the lantern can damage the piston rod (K)
and the shaft of the valve disc (16).
► Secure the lantern when unscrewing the actuator.
Maintenance
Disassembling the Valve
430BAL008326EN_3
42