Before starting any maintenance, servicing or repair work, disconnect the
valve from the power supply and secure it against inadvertently being
switched back on again.
•
Only allow a qualified electrician to carry out any work on the electrical power
supply.
•
Check the electrical equipment of the valve at regular intervals. Immediately
remedy loose connections and molten cables.
•
If work on live parts cannot be avoided, call in a second person, who can
operate the main switch in case of an emergency.
•
The housing sockets (402) have very sharp edges. When transporting and
installing the valve be sure to wear suitable protective gloves.
•
When the valve switches, when the valve seat is being cleaned or if a seal is
defective, medium (product cleaning medium) exits from the leakage outlet
(15). Collect this liquid in a suitable container such as a funnel or a drip pan
and discharge it in a safe manner. Observe the instructions in the safety data
sheets issued by the cleaning agent manufacturers.
Safety
430BAL008326EN_3
07.02.2022
17