Only use sound absorber (21, 26) specified in chapter “Technical data” . Do not
grease these spare parts before fitting them.
Fig.24
Caution!
► On VARIVENT actuators with a vent hole in the actuator cover the
control top may only be fitted without O-ring (54)!
Carry out the following steps:
1.
Take out the O-rings (31, 53, 54) and replace them with new ones.
2.
Check that the control air can exit freely from the sound absorbers (21, 26),
filter (5.1) and reflux valveVe (26.1) and replace the parts if necessary.
®
Done
Carrying out a Reset – Back to Default Standard
Carry out the following steps:
1.
Press the reset key for 3-7 sec.
2.
After the button has been pressed for 3 seconds, the reset is initiated and the
LED goes off.
3.
The learning process starts automatically 1-2 seconds after reset red
continuous light for 1-2 seconds.
®
Done
Maintenance
430BAL014475EN_2
50
03.09.2021