6.4.1
Electrical 24V DC Wiring
Fig.10
Danger
Only allow properly qualified staff to carry out work on the electrical
equipment. Prior to establishing electrical connections check the maximum
permissible operating voltage.
►
Carry out the following steps:
1.
Release the cheese head screws (25) and take off the cap (7).
2.
Pass the cable (Ø6-12 mm) through the cable gland (24) and connect it to the
terminals (K) in the control top in accordance with the wiring diagram. Use
wires with ferrules, max. 1.5 mm².
3.
Secure the cable in the cable gland at a torque of 2.5 Nm.
Hint!
The electrical cable must be long enough to allow the control top to be
removed via the switch bar!
The cables must be suitable for use in the required temperature range!
Assembly and installation
Electrical connections
430BAL014475EN_2
30
03.09.2021
Содержание T.VIS M-20 FDD
Страница 57: ...Appendix 430BAL014475EN_2 03 09 2021 57...
Страница 58: ......