Fig.18
Pneumatic block (8.2) for max. 1 solenoid valve
Hint!
When using the pneumatic block (8.2) with one valve plate (65), the
groove (65.12) must be fitted on the left side. The two screws (66) are
located in the left mounting holes.
Tighten the screws (66) to a max. tightening torque of 0.8 Nm.
10.6.4 Removing the sensor module
Fig.19
Carry out the following steps:
1.
Loosen all the cables and connectors on the sensor module and remove
them.
2.
Unscrew and remove the screws (53).
Maintenance
Dismantling the Control Top into its Components
430BAL014475EN_2