5.4
Switching point tolerances and signal output
5.4.1
Signal output
Hint!
Only use preset DIP switch configuration. Further positions lead to
non-intended use.
Main stroke - signal output
Pilot valve actuation
Valve position
DIP switch
Illumination
Feedback
PV Y1
PV Y2
PV Y3
1
Green
Yellow
S1
S2
0
0
0
not actuated
0
1
0
1
0
1
0
0
main stroke / stroke in S1 tolerance
0
1
0
1
0
1
0
0
Main stroke / stroke movement
0
0
1Hz
0
0
1
0
0
main stroke / stroke in S2 tolerance
0
0
1
0
1
0
0
0
main stroke / stroke in S2 tolerance
0
0
1
0
1
0
0
0
Main stroke / stroke movement
0
1Hz
0
0
0
0
0
0
not actuated
0
1
0
1
0
5.4.2
Signal output inverted
Main stroke - signal output inverted
Pilot valve actuation
Valve position
DIP switch
Illumination
Feedback
PV Y1
PV Y2
PV Y3
1
Green
Yellow
S1
S2
0
0
0
not actuated
1
0
1
0
1
1
0
0
main stroke / stroke in S2 tolerance
1
0
1
0
1
1
0
0
Main stroke / stroke movement
1
1Hz
0
0
0
1
0
0
main stroke / stroke in S1 tolerance
1
1
0
1
0
0
0
0
main stroke / stroke in S1 tolerance
1
1
0
1
0
0
0
0
Main stroke / stroke movement
1
0
1Hz
0
0
0
0
0
not actuated
1
0
1
0
1
5.5
Lubricants
Lubricants
Material no.
Rivolta F.L.G. MD-2
413-071
PARALIQ GTE 703
413-064
Technical data
Switching point tolerances and signal output
430BAL014475EN_2
26
03.09.2021