10.4
Dismantling the Control Top into its Components
10.4.1 Variants of the Control Top
The control top can be fitted with:
•
3 solenoid valves (63) and without or with 1 logic element NOT (64) or
•
2 solenoid valves (63) and 1 control plate (65) and without or with 1 logic
element NOT (64) or
•
1 solenoid valve (63) and 2 control plates (65) and without or with 1 logic
element NOT (64) or
•
1 solenoid valve (63) or
•
without solenoid valve with 1 control plate (65).
10.4.2 Removing the Cap
Fig.66
Danger
Electrical voltage
Danger to life
► Switch off the voltage supply and the control air before removing the
control top.
Carry out the following steps:
1.
Undo the 3 screws (25) of the cap (7) and remove the cap (7) from the base
(5).
®
Done
Maintenance
Dismantling the Control Top into its Components
430BAL010697EN_2
15.04.2020
95
Содержание T.VIS M-15
Страница 6: ...430BAL010697EN_2 6 15 04 2020...
Страница 53: ...Fig 27 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 53...
Страница 55: ...Fig 28 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 55...
Страница 111: ...14 Spare parts list Switch bar T VIS M 15 Fig 82 Spare parts list Switch bar T VIS M 15 430BAL010697EN_2 15 04 2020 111...
Страница 119: ...Appendix 430BAL010697EN_2 15 04 2020 119...
Страница 120: ......