1.
Unscrew the proximity switch by one full turn (360°) to set the gap (a) in the
range from 0.5 to 1.0 mm.
Fig.57
2.
Tighten the lock nut (11).
3.
Secure the connector (10), which has already been electrically connected to
the control top, to the proximity switch using the cap nut M12 (10.1).
®
The LED on the proximity switch must now be lit in operating mode.
®
Done.
Checking the function
Carry out the following steps:
1.
Check the feedback function by actuating solenoid valve Y3.
®
The LED must go out.
®
Done
®
The proximity switch has now been adjusted and checked.
7.7
Adjusting the Proximity Switch in the lantern of PMO Valve Type M/2.0
Fitting the proximity switch holder
Carry out the following steps:
1.
Position the nut (2) against the slot (4.1) in the lantern (4) from the inside and
hold it in position with a finger.
Fig.58
2.
Secure the sliding piece (1) with the countersunk screw (3). Pay attention that
the orientation is as shown in the diagram. The mounting hole (1.1) must face
in the direction of the housing (5).
Start-up
Adjusting the Proximity Switch in the lantern of PMO Valve Type M/2.0
430BAL010697EN_2
84
15.04.2020
Содержание T.VIS M-15
Страница 6: ...430BAL010697EN_2 6 15 04 2020...
Страница 53: ...Fig 27 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 53...
Страница 55: ...Fig 28 Assembly and installation Electrical connections 430BAL010697EN_2 15 04 2020 55...
Страница 111: ...14 Spare parts list Switch bar T VIS M 15 Fig 82 Spare parts list Switch bar T VIS M 15 430BAL010697EN_2 15 04 2020 111...
Страница 119: ...Appendix 430BAL010697EN_2 15 04 2020 119...
Страница 120: ......