Instructions for use and maintenance
This manual is owned by GEA Niro Soavi Any reproduction, even partial, is prohibited.
08C100-3C0
GEA Niro Soavi
210
FAULT
POSSIBLE CAUSE
REMEDY
10. Total lack of
homogenization pressure
• Reduced flow rate
• See fault 3
• Damaged homogenizing
valve
• Clean or replace
(See chapter 7
"MAINTENANCE")
• No air pressure in
pneumatic circuit
• Check efficiency and
functionality of the
pneumatic system
(See chapter 7
"MAINTENANCE")
• Defective pneumatic
cylinder
• Replace
11. Homogenization pressure
is not reached
• Not enough feeding
• Feed the machine properly
• Blocked homogenizing
valve
• Dismantle, clean
(See chapter 7
"MAINTENANCE")
• Worn homogenizing valve • Replace (See chapter 7
MAINTENANCE)
• Faulty pressure gauge
• Replace (See chapter 7
"MAINTENANCE")
• Damaged homogenising
unit shaft
• Replace (See chapter 7
"MAINTENANCE")
12. Oscillating homogenizing
pressure
• Air or bubbles in the
product
• Eliminate
• Air in the compression
head
• Release pressure, then
apply pressure again
• Not enough or unsteady
feeding pressure
• Feed the machine properly
• Incorrect operation of the
suction or delivery valves
• Clean or replace
(See chapter 7
"MAINTENANCE")
• Incorrect operation of the
pneumatic control
• Check pneumatic
system (See chapter 7
"MAINTENANCE")
• Unsteady backpressure
• Provide stable
backpressure
13. Excessive noise of the
homogenizing unit
• Worn homogenizing valve
• Replace (See chapter 7
"MAINTENANCE")
• Resonance in the plant
• Modify the backpressure;
install pulsation damper
downstream; move the
existing damper further
downstream; contact
GEA
Niro Soavi