![GEA Niro Soavi One7TS Скачать руководство пользователя страница 156](http://html1.mh-extra.com/html/gea/niro-soavi-one7ts/niro-soavi-one7ts_instruction-manual_572298156.webp)
Instructions for use and maintenance
This manual is owned by GEA Niro Soavi Any reproduction, even partial, is prohibited.
07C100-7C0
GEA Niro Soavi
154
SHEET B[a]
HOMOGENIZING UNIT -
Checking/renewing homogenizing valves
CAUTION:
Activities to be carried out after maintenance shutdown of the machine (see paragraph 7.3.3)
RESOURCES AND TOOLS
: MAINTENANCE ENGINEER
JOB FREQUENCY
: EVERY 500 HOURS (CHECK)
TIME REQUIRED
: 20 MINUTES
DESCRIPTION:
Instructions for disassembly
For the maintenance operations of the pneumatically controlled homogenizing unit, proceed as
follows (referring to Figure 7-25):
- disconnect the connections for the pneumatic drive of the piston on the machine's front panel
CAUTION:
The homogenizing unit is heavy!
When removing, handling and positioning, use both hands and appropriate personal
protective equipment in order to prevent injury.
- Remove the pneumatic drive unit
(2)
, joined with screws
(4)
to the supporting flange
(3)
- Unscrew the nuts of the stud bolts joining the supporting flange
(3)
and homogenising chamber.
- To extract the impact head assembly
(6)
, first remove the passage head
(10)
, gasket
(9)
and
impact ring
(5)
.
- If the vibration is too great, it is necessary to check the surface of the spindle of the impact head
(6)
and, if necessary, replace the guide bushings
(7)
made of self-lubricating plastic
- Remove the homogenising unit assembly
(8)
and rest on a work surface.
Содержание Niro Soavi One7TS