![GEA EL44 Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/gea/el44/el44_instruction-manual-and-installation-instructions_3983910106.webp)
Maintenance
Change the oil of the bearing housing
2018-9015-003
03-2015
10.18
Torque bolts
Every 200 hours
Check torque of :
● mudguard bolts;
● dust shield bolts;
● transportation support bolts;
● components fastened on the spreader.
Refer to section Technical data - Bolt torque chart.
10.19
Change the oil of the bearing housing
Every 200 hours
Refer to section Technical data - Lubricant specifications.
● Place a container under the drain
plug (1) to collect the oil.
● Remove the filling plug (2) located
between the grease fitting and the
air vent.
● Unbolt the drain plug (1).
● Reinstall the drain plug (1) when the
housing is drained.
● Add SAE 80W90 bearing oil until the
level is even with the top of the shaft.
● Clean the filling plug (2) and bolt it
back on.
2
1