– 54 –
4. Attach the capillary tubing to the copper
extension tube using the WR97X10035 (5/16-in.
to .079) capillary-reducing connector.
Note:
When using a capillary-reducing connector,
make sure the capillary tube protrudes thru the
opposite end of the connector.
5. Since this connector does not have an internal
stop, bend the capillary tube slightly at the
opening to create a stop.
6. Pull the capillary tube out 1/8 inch, apply a
single drop of LokPrep, and reinsert before
compression.
Bend
Protrusion
Compressed Reducer
Extension Tube
Removed Tubing
4. Lift the toekick off the bottom 2 tabs.
Toekick and Vent Panel
The toekick and vent panel must be removed to
access the system tray.
To remove the toekick and vent panel:
Note:
Installation instructions permit a removable
wood toekick panel to be installed on the unit
provided it is secured with Velcro® or magnets.
1. Remove the wood or stainless steel convertible
drawer panel. (See
Installation Instructions
.)
2. Insert a large,
fl
at blade screwdriver between
the top of the toekick and the bottom of the vent
panel, as shown in the photo below.
3. Push the screwdriver down while pulling out the
top of the vent panel. Repeat on opposite side.
Tab
5. Remove the 2 Phillips-head screws from the
bottom and 2 recessed Phillips-head screws
from the top of the vent panel.