34
DRAIN PUMP AND MOTOR ASSEMBLY
The pump system consists of an AC motor and pump
assembly, a bellows type sump hose, air bell, and an
external cabinet drain hose.
The drain pump and motor assembly is mounted on the
base at the right front corner of the cabinet.
When the wash or rinse cycle is completed, the timer
energizes the pump motor to remove water from the tub.
The pump motor remains in operation throughout the
spin cycle.
To Test Drain Pump Motor Windings:
1. Disconnect the washer from electrical supply.
2. Remove front access panel from washer.
3. Disconnect harness plug from pump motor.
4. Check resistance of motor windings. Resistance
should be approximately 4.8 ohms ±10% @ 77°F.
To Remove or Replace Drain Pump Motor:
1. Disconnect the washer from electrical supply.
2. Remove front access panel from washer.
3. Remove bolts (2) securing motor cover to pump.
4. Disconnect electrical harness plug from pump
motor.
5. Remove clamp securing sump hose to pump.
6. Remove clamp securing exterior drain hose to
pump.
7. Remove two hex head screws securing the drain
motor and pump assembly to cabinet base.
8. Reverse procedure to install new drain motor and
pump assembly.
AIR BELL AND PRESSURE CONNECTING TUBE
In order to provide enough air pressure to activate the
water level control switch, a large volume of air must be
compressed and transferred to the water level control.
This is accomplished by using an air bell and black
rubber tubing.
The air stored in the air bell is compressed by the weight
of the water in the tub. The resulting pressure is then
transferred to the water level control through the black
rubber tubing.
To Remove or Replace Air Bell:
1. Disconnect washer from electrical supply.
2. Remove two screws securing the front service
panel.
3. Remove the service panel by pulling down.
4. Remove drain hose from drain and empty any
remaining water in hose. Use a large pot or pan.
5. Remove clamp securing air bell to sump hose and
remove connecting tube from air bell.
6. Install new air bell and connecting tube.
7. Reverse procedure to reassemble.
NOTE:
Seal air connecting tube to air bell and air bell to
sump hose using waterproof glue. DO NOT plug con-
necting tube opening.
Содержание WSXH208T
Страница 1: ......
Страница 7: ...6 SCHEMATIC DIAGRAM ...
Страница 8: ...7 TIMER CYCLE CHART ...
Страница 10: ...9 WIRINGDIAGRAM ...
Страница 16: ...15 NOTES ...
Страница 40: ...39 ...
Страница 41: ...40 ...
Страница 42: ...41 ...
Страница 43: ...42 TIMER DIAGNOSTIC AID Cut Out Center Hole Place Over Timer Knob and Align With STOP Position ...
Страница 44: ...RETURN MAIN MENU ...
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......