32
2. Remove rear service panel.
3. Remove belt by turning tub drive pulley and rolling
belt off pulley. The belt is elastic and is designed to
"give" enough to remove and install in this manner.
4. Remove one screw to take off the motor connector
shield.
5. Disconnect the wiring harness connector block and
ground wire.
6. Remove motor mounting bolts (4).
7. Slide motor to front while supporting to remove.
8. Reverse procedure to reinstall, making sure that
belt tracks in the center of the tub pulley. Adjust by
moving belt on motor pulley if required.
DRIVE BELT
The drive belt (6 rib flat Poly-V) is used to transmit
power from the motor pulley to the tub. The belt is
constructed of a material that stretches, which makes
belt tension adjustments unnecessary.
To Remove or Replace the Drive Belt
1. Disconnect washer from electrical supply.
2. Remove rear service panel.
3. Remove belt by turning tub drive pulley and rolling belt
off pulley. The belt is elastic and is designed to "give"
enough to remove and install in this manner.
4. Reverse procedure to reinstall, making sure that belt
tween terminals 5 and 6. Resistance value should
be less than 5 ohms (the wide range of resistance
is due to measuring through the brushes of the
motor.)
3. Check resistance of tachogenerator between termi-
nals 1 and 2. Resistance value should be 135
ohms.
4. Check the continuity of the motor protector be-
tween terminals 7 and 8. Resistance should be less
than 1 ohm.
To Remove or Replace the Drive Motor
1. Disconnect washer from electrical supply.
terminals 3 and 4. Resistance should be 0.37
ohms. See motor diagram below.
2. Check resistance of armature (rotor) windings be-
9
10
STATOR
WINDING
FULL FIELD
STATOR
WINDING
TAPPED FIELD
TACHO -
GENERATOR
ARMATURE &
BRUSHES
MOTOR
THERMAL
PROTECTOR
Содержание WSXH208T
Страница 1: ......
Страница 7: ...6 SCHEMATIC DIAGRAM ...
Страница 8: ...7 TIMER CYCLE CHART ...
Страница 10: ...9 WIRINGDIAGRAM ...
Страница 16: ...15 NOTES ...
Страница 40: ...39 ...
Страница 41: ...40 ...
Страница 42: ...41 ...
Страница 43: ...42 TIMER DIAGNOSTIC AID Cut Out Center Hole Place Over Timer Knob and Align With STOP Position ...
Страница 44: ...RETURN MAIN MENU ...
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......