26
pole, double-throw switch connected to an air bell at the
sump hose. A black plastic tube connects the pressure
switch to the air bell. Its purpose is to determine the
water level within the tub and control the operation of the
water fill valve. As the water level rises in the tub, air in
the pressure tube is compressed and forced against the
diaphragm in the water level control switch.
DO NOT ATTEMPT TO ADJUST THE RANGE OF THE
WATER LEVEL CONTROL.
To Test Water Level Control:
Do not condemn a water level control until the entire
system has been examined and tested. For example, if
the air bell, located at the sump area, has filled with
water, the water level control will overfill the tub.
1. If any water is remaining in the tub, empty by
advancing timer to a drain cycle (see cycle chart).
2. After water has drained out, turn off washer and
remove front service panel.
3. Examine the air bell. There should not be any water
or foreign objects visible in the air bell.
4. Turn timer to a fill cycle. After the water level control
has been satisfied, push and turn the timer to
OFF, open door and measure the depth of water.
The depth should be 4-5/8" ± 3/8". If not, drain
washer and continue with step 5.
5. Disconnect the washer from electrical supply.
6. Remove the wire from the terminal 1 on the water
level control.
7. Check continuity between terminals 1 and 2. Con-
tinuity should exist. If no continuity exists, replace
the water level control.
8. Remove the pressure tube from water level control
and attach a short piece of scrap pressure tube to
water level control. Blow into tube until water level
control trips and tightly clamp end of tubing shut.
9. Recheck continuity between terminals 1 and 2. No
continuity should exist. Check for continuity be-
tween terminals 1 and 3. Continuity should exist.
Leave the clamped scrap tubing attached to the
water level control for a few minutes. If water level
control trips during this time frame, the internal
diaphragm is leaking and the water level control
must be replaced.
To Remove or Replace Water Level Control:
1. Disconnect washer from electrical supply.
2. If dryer is stacked on washer, remove clothes dryer
from top of washer.
Note:
It may possible to slide
dryer back far enough to access water level control
without removing the dryer, depending upon indi-
vidual installation.
3. If freestanding or undercounter installation, remove
the top panel.
4. Remove one (1) screw securing the water level
control to cabinet.
5. Remove wiring to the water level control.
6. Remove the water level control pressure tube.
7. Reverse procedure to install new water level con-
trol.
WATER TEMPERATURE SELECTOR CONTROL
The water temperatures for washing and rinsing are set
by using the water temperature selector. Turn the knob
to the desired water temperature combination. Several
wash/rinse water temperature combinations are avail-
able.
Selections are:
COLD-COLD,WARM-COLD,WARM-WARM,
HOT-COLD, and HOT-WARM (HOT-WARM is not
used on domestic models).
To Test Water Temperature Control Switch:
Continuity of the water temperature control switch con-
tacts can be checked using the chart or the wiring and
schematic diagram on the back side of the service panel.
To test, remove wires from switch and check continuity
between terminals as indicated on the water temperature
control switch chart found on the units electrical diagram.
WATER TEMPERATURE SWITCH
CIRCUIT
WASH/RINSE TEMP
1-3
1-5
2-4
C/C
X
W/C
X
X
W/W
X
X
X
H/C
X
H/W
X
X
To Remove or Replace Water Temperature Control
Switch:
1. Disconnect the washer from electrical supply.
2. If dryer is stacked on washer, remove clothes dryer
from top of washer.
Note:
It may possible to slide
dryer back far enough to access water temperature
control switch without removing the dryer, depending
upon individual installation.
3. If freestanding or undercounter installation, remove
the top panel.
6. Remove knob from water temperature control
switch.
7. Remove two screws securing the water tempera-
ture control switch to cabinet.
Содержание WSXH208T
Страница 1: ......
Страница 7: ...6 SCHEMATIC DIAGRAM ...
Страница 8: ...7 TIMER CYCLE CHART ...
Страница 10: ...9 WIRINGDIAGRAM ...
Страница 16: ...15 NOTES ...
Страница 40: ...39 ...
Страница 41: ...40 ...
Страница 42: ...41 ...
Страница 43: ...42 TIMER DIAGNOSTIC AID Cut Out Center Hole Place Over Timer Knob and Align With STOP Position ...
Страница 44: ...RETURN MAIN MENU ...
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......