Simon Security System
54
System Access Codes
The factory default settings are 4-digit access codes, but the default codes will change whenever
Option 54 (Access Code Length) is reset. The default for each access code length is listed.
32
PIR motion sensor or sound sensor‡ No report
Silent
I
No
No
01234
34
Carbon Monoxide Alarm
Emergency
I
Yes
Yes
01234
35
Entry/Exit Delay Interior PIR Motion
Intrusion
S
No
Yes
234
36
Special Intrusion: such as gun cabinets and wall safes. Reports as tamper if tripped.
Intrusion
I
Yes
Yes
1234
37
Light Switch Control: X10 Modules turn either on or off when a door is opened. No
report.
Silent
I
No
Yes
01234
38
Auxiliary: Water Sensors.
Trouble Beeps
I
Yes
Yes
01234
Sensor Group Characteristics
Ty
p
e
Name/Application
Siren Type
De
la
y
R
est
or
al
S
upe
rv
is
or
y
Active
in
Levels
* This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
§ This type is required for UL-listed residential fire alarm applications.
‡ This type has not been investigated by UL.
Delays:
I = Instant Delay (no delay, immediate alarm)
S = Standard Delay (alarm sounds after programmed entry delay time)
F = Follower Delay (alarm sounds immediately if entry/exit delay is not active, otherwise alarm sounds after programmed
entry delay time)
Home Control Planning Table
Module
Activated by
Time Activated
Unit #
Type
Location
Sensor
Entry/Exit
Start Time
Stop Time
Example
Lamp
Hall lamp
Motion
Yes
8 p.m.
10:30 p.m.
1
2
3
4
5
6
7
8
System Access Codes
Type
Default
a
Installer Settings
Utility Access Code 1
654321, 54321, 4321, or 321
Utility Access Code 2
654321, 54321, 4321, or 321
Master Access Code
123456, 12345, 1234, or 123