Simon Security System
46
4.
When you finish testing the system, call the central station to verify that the
alarms were received.
Pager Communication
Use the following table to determine what the numeric message is reporting.
2-Way Voice Operation
To initiate an audio session, the central station operator must perform the following
steps:
Note
Panel voice announce-
ments are silenced during
AVM sessions. If the opera-
tor does not terminate the
session correctly, panel
announcements may not
occur for up to 90 seconds
after the operator hangs up.
1.
After the panel has completed reporting the alarm, pick up the CS phone and press
the
‚
button to start the audio session.
2.
Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 to listen.
3.
Press 99 to terminate the session.
User Codes for Opening and Closing Reports
Arm or Disarm from:
Reports as User:
Panel or Remote Handheld Touchpad
0
Keychain Touchpad
1-24 (sensor number)
Master Code
30
Access Codes 1-5
31-35
Panic Code
36
Pager Reporting Message
Reports
Numeric Message
Phone Test
-101 -101
AC Power Restoral
-102 -102
AC Power Failure
-103 -103
Latchkey
-104 -104
No Activity
-105 -105
Panic Code
-106 -106
Emergency
-107 -107
Intrusion
-108 -108
Fire
-109 -109
Openings
-110 -110
Closings
-111 -111
Fail to Open
-112 -112
Fail to Close
-113 -113