![GE Simon Security System Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/ge/simon-security-system/simon-security-system_installation-instructions-manual_4158263039.webp)
Simon Security System
32
¾
To reset Numeric Pager/Voice Event Notification Phone Mod 3 (return to
default), press:
Delete—Option #—44—DONE.
Option 45: Sensor Alarm Restoral Report (Default = off)
Determines whether the panel reports sensor alarm restorals (on), or not (off). The fol-
lowing table describes the possible settings.
¾
To turn on Sensor Alarm Restoral Report, press:
Add—Option #—45—1, 2, or 3—DONE.
¾
To turn off Sensor Alarm Restoral Report, press:
Delete—Option #—45—DONE.
Option 46: Fire Shutdown - AVM (Default = off)
Determines whether system sirens are silenced during a 2-way audio session (on) or
not (off). Beeps sound every 10 seconds while sirens are silenced.
¾
To turn on Fire Shutdown - AVM, press:
Add—Option #—46—DONE.
¾
To turn off Fire Shutdown - AVM, press:
Delete—Option #—46—DONE.
Option 47: AVM Mode (Default = off)
Determines whether the panel hangs up and waits for a callback from the central sta-
tion operator before starting an audio session (on), or stays on line with the central sta-
tion for an instant audio session (off).
Note
Option 33: Audio Verification
must be on for this feature to
work.
¾
To set AVM Mode to Callback, press:
Add—Option #—47—DONE.
¾
To set AVM Mode to Instant, press:
Delete—Option #—47—DONE.
Option 48: Panic Talk - AVM (Default = off)
Determines whether the central station operator can talk to the user during a silent
alarm (on) or just listen in on the premises (off).
Silent alarms occur when sensors learned into groups 02 or 03 are tripped, when the
Panic Code is entered, or when the panel Police button is pressed and Option 74: Silent
Panel Police Panic is turned on.
Note
Option 33: Audio Verification
must be on for this feature to
work.
¾
To turn on Panic Talk - AVM, press:
Add—Option #—48—DONE.
¾
To turn off Panic Talk - AVM, press:
Sensor Alarm Restoral Settings
Setting
When Restorals are Reported
Off
No restoral reporting
1
Immediately after sensor is closed or restored
2
After siren timeout expires
3
When system is disarmed
Содержание Simon Security System
Страница 66: ...Simon Security System 59...
Страница 67: ...Simon Security System 60...