Simon Security System
53
Sensor Group Characteristics
Ty
p
e
Name/Application
Siren Type
De
la
y
R
est
or
al
S
upe
rv
is
or
y
Active
in
Levels
00
Fixed Panic: 24 hour audible fixed emergency button
Intrusion
I
No
Yes
1234
01
Portable Panic: 24 hour audible portable emergency buttons
Intrusion
I
No
No
1234
02
Fixed Panic: 24 hour silent fixed emergency buttons. Status light will not blink.
Silent
I
No
Yes
01234
03
Portable Panic: 24 hour silent portable emergency buttons. Status light will not blink.
Silent
I
No
No
01234
04
Fixed auxiliary: 24 hour auxiliary sensor
Emergency
I
No
Yes
01234
05
Fixed Auxiliary: 24 hour emergency button. Siren shut off confirms CS report
Emergency
I
No
Yes
01234
06
Portable Auxiliary: 24 hour portable auxiliary alert button
Emergency
I
No
No
01234
07
Portable Auxiliary: 24 hour portable auxiliary button. Siren shut off confirms CS report
Emergency
I
No
No
01234
08
Special Intrusion: such as gun cabinets and wall safes.
Intrusion
I
Yes
Yes
1234
09
Special Intrusion: such as gun cabinets and wall safes.
Intrusion
S
Yes
Yes
1234
10
Entry/Exit Delay: Entry/Exit Delay that require a standard delay time. Chime
Intrusion
S
Yes
Yes
24
13
Instant perimeter: Exterior doors and windows. Chime
Intrusion
I
Yes
Yes
24
14
Instant Interior: Interior doors
Intrusion
F
Yes
Yes
234
15
Instant Interior: Interior PIR motion sensors*
Intrusion
F
No
Yes
234
16
Instant Interior: Interior doors
Intrusion
F
Yes
Yes
34
17
Instant Interior: PIR motion sensors and Sound sensors*
Intrusion
F
No
Yes
34
18
Instant Interior Cross Zone: PIR motion sensors*
Intrusion
F
No
Yes
34
19
Delayed Interior: interior doors that initiate a delay before going into alarm*
Intrusion
S
Yes
Yes
34
20
Delayed Interior: PIR motion sensors that initiate a delay before going into alarm*
Intrusion
S
No
Yes
34
21
Local Instant Interior: 24 hour local alarm zone protecting anything that opens and
closes. No Report
Intrusion
I
Yes
Yes
1234
22
Local delayed interior: same as group 21, plus activation initiates a delay before going
into alarm. No report.*
Intrusion
S
Yes
Yes
1234
23
Local instant Auxiliary: 24 hour local alarm zone protecting anything that opens and
closes.‡ No report
Emergency
I
Yes
Yes
01234
24
Local Instant Auxiliary: 24 hour local alarm zone protecting anything that opens and
closes. Sirens shut off at restoral. No report.*
Emergency
I
Yes
Yes
01234
25
Local Special Chime: Notify the user when a door is opened. Sounds emit from a local
annunciator.* Direct Bypass and Unbypass when no Special Motion Chime sensors are
in the security system. No report
Three Beeps
I
No
Yes
01234
26
Fire: 24 hour fire, rate-of-rise heat, and smoke sensors§.
Fire
I
Yes
Yes
01234
27
Lamp control or other customer feature.‡ No report
Silent
I
Yes
Yes
01234
28
PIR motion sensor, sound sensor, or pressure mat.‡ RF Thermostat. No report
Silent
I
No
Yes
01234
29
Auxiliary: Freeze Sensors
Trouble Beeps
I
Yes
Yes
01234
* This type is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.
§ This type is required for UL-listed residential fire alarm applications.
‡ This type has not been investigated by UL.
Delays:
I = Instant Delay (no delay, immediate alarm)
S = Standard Delay (alarm sounds after programmed entry delay time)
F = Follower Delay (alarm sounds immediately if entry/exit delay is not active, otherwise alarm sounds after programmed
entry delay time)