LCD KEYPAD
23
Zone
Low Battery, Press
A wireless device has a low battery. Press
to identify the
zone.
Zone
Lost, Press
r
A wireless or multiplexed zone device is not reporting to the
control. Press
to identify the zone.
Zone
Trouble, Press
r
A zone is experiencing some form of trouble (probably wiring).
Press
to identify the zone.
DEVICE NUMBERS FOR REPORTING
The following table provides the device numbers that will be reported for trouble conditions.
Table 9-1
KEYPAD
PARTITION
1
2
3
4
5
6
7
8
1 192 193 194 195 196 197 198 199
2 200 201 202 203 204 205 206 207
3 208 209 210 211 212 213 214 215
4 216 217 218 219 220 221 222 223
5 224 225 226 227 228 229 230 231
6 232 233 234 235 236 237 238 239
7 240 241 242 243 244 245 246 247
8 248 249 250 251 252 253 254 255
10. MAXIMUM WIRE RUN
These numbers are for one keypad at the end of the wire. When connecting more than one keypad
to the end of the wire, a heavier gauge wire will be required.)
FOR UL COMMERCIAL FIRE SYSTEMS, A MINIMUM 18 AWG WIRE SHALL BE USED.
WHEN CONNECTED TO
NX CONTROL PANEL
WHEN CONNECTED TO NX-320E
Length in feet
Wire Gauge
Wire Gauge
250' 24
22
500 20
18
1000 18
16
1500 16
14
2500 14
12