background image

 

LCD KEYPAD 

9

 

6b.  ADJUSTING THE VIEW & BRIGHTNESS OF THE LCD 

ACTION 

 

RESULT 

 

 

 

 

 

 

 

 

 

 

Prompts to “Please Enter Your Code". 

 

[master code]

 

 

 

 

 

 

 

 

Prompts to raise or lower the View angle. 

 

 

or 

 

 

 

 

 

 

 

 

Using the scroll keys to the right of the LCD, you 
can raise or lower the viewing angle of the text.  

 

  

 

 

 

 

 

 

 

Advances to the Brightness option.   

Prompts to brighten or dim the LCD lighting. 

 

 

or 

 

 

 

 

 

 

 

 

Use the scroll keys again to adjust to desired 
brightness. 

 

  

 

 

 

 

 

 

 

Exits this mode. 

 
 

6c.  CUSTOM MESSAGES 

 

  I M P O R T A N T       N O T E S    

  
1) 

When using standard NX-148 keypad(s) and NX-148E keypad(s) in the same system, it is 

necessary to use a NON-“E” keypad to program the custom messages.  The NON-“E” keypads 

can be identified by the fact that they do not display a menu when 

 

is pressed. 

2) 

The messages (custom, zone, and shutdown) are transferred to other LCD keypads after this mode 

is exited.  All keypads must be addressed and enrolled for this to happen. 

3) 

Use the 

 

 function to set the keypad numbers prior to programming custom messages.  

4) 

If a keypad is added after messages are programmed, you should either program ALL messages in 

it, or enter custom message programming on an existing keypad and make changes. This is to 

prevent accidentally overwriting existing messages. Refer to 

 

 option to prevent overwriting 

the custom message only. 

 

ACTION 

 

RESULT 

 

 

 

 

 

 

 

 

 

 

Prompts to “Please Enter Your Code". 

 

[program code]

 

 

 

 

 

 

 

 

The LCD will now prompt you to enter message 
number followed by 

#

.   

Zones 1 through 192 custom messages are 
message numbers 1-192 respectively. 
Message 193 - Custom message top line. 
Message 194 - Custom message bottom line. 
Message 195 - Shutdown message top line. 
Message 196 - Shutdown message bottom line.  

Содержание NX-148E - Security NetworX LCD Keypad

Страница 1: ...NetworX Series NX 148E LCD Keypad Installation and Setup Includes models NX 148E NX 148E CF and NX 148E CF W...

Страница 2: ...approval of GE Security Please refer to the current GE Security product catalog for detailed warranty information Main 800 727 2339 Technical Support 888 437 3287 Outside the US 903 845 6941 Sales Li...

Страница 3: ...12 7A READING THE EVENT LOG 12 7B SET ELAPSED TIME IN MINUTES SINCE LAST AUTOTEST 13 7C SET SYSTEM TIME AND DATE 14 7D ADJUST KEYPAD TONE 14 7E VIEW ZONE STATUS 14 7F VIEW ALARM MEMORY 15 7G TEST FUNC...

Страница 4: ...location the top line of the LCD screen will display the location number on the left and the segment number on the right The bottom line of the display will show the current data This data will be dis...

Страница 5: ...programming Refer to feature on page 9 for custom messages Custom zone descriptions and messages are stored character or ASCII data type This information is programmed using the bottom line of the dis...

Страница 6: ...LL MASTER RUMPUS STAIRS WINDOW BATHROOM DURESS HEAT MICROWAVE SAFE STORAGE WING BEAM EAST HOLDUP MOTION SENSOR STUDY WIRELESS BEDROOM EMERGENCY HOUSE NORTH SHOCK TAMPER YARD BUTTON EXIT INFRARED NURSE...

Страница 7: ...takes about 6 seconds To load the factory defaults for the LCD keypad enter the Program Mode from a different keypad does not have to be LCD keypad and follow the same procedures The two line Custom a...

Страница 8: ...Menu Select an Option Press for help These are samples of the displays that will scroll automatically in the Function Menu Table 6 1 provides a list of the Function Menu items as well as page referen...

Страница 9: ...he messages custom zone and shutdown are transferred to other LCD keypads after this mode is exited All keypads must be addressed and enrolled for this to happen 3 Use the function to set the keypad n...

Страница 10: ...MESSAGES IN LANGUAGE 2 Tip Exit mode prior to changing languages ACTION RESULT Keypad is now toggled to the second language Proceed with steps for usual programming 6e SET KEYPAD OPTIONS ACTION RESULT...

Страница 11: ...equired message to be displayed for any reason If there is a system trouble r will still show the Service Required menu 8 MASTER KEYPAD Enable Multi partition Mode 9 CUSTOM MESSAGE Enable Custom Messa...

Страница 12: ...ZN Lost Zone Lost A wireless or multiplexed zone device is not reporting to the control Duress Duress The control has been armed or disarmed with a Duress code Man Fire Manual Fire Keypad Fire has be...

Страница 13: ...curred on an expander auxiliary output Data Lost Data Lost Communication of a signal has failed log only event Walk test Walk Test A zone Walk Test mode has been activated End Test End Test Test has b...

Страница 14: ...steps until the entire time and date is set 7d ADJUST KEYPAD TONE ACTION RESULT Prompts to use the scroll keys right of the display to raise or lower the tone to raise the tone to lower the tone The k...

Страница 15: ...and LED indicators will flash Press any key to end test 7i LIGHT CONTROL FOR X 10 DEVICES When used in conjunction with an X 10 output device such as the NetworX NX 507E NX 508E NX 534E or NX 540E thi...

Страница 16: ...e code Prompts for the House Code of the device Repeat steps 3 and 4 until all devices have been programmed Exits the function 7k CHANGE LANGUAGES ACTION RESULT Keypad toggles to the second language K...

Страница 17: ...ly Output 3 enable Arm only Output 2 enable Reserved Output 1 enable Open Close Rprt Bypass enable Arm Disarm partition number Default allows access to ALL partitions The first keypress will remove ac...

Страница 18: ...ontrol Panel Installation Manual while system is disarmed Causes the control to seize the phone line for a download A valid user code may be required if feature is enabled in location 41 of the contro...

Страница 19: ...if ANY area has a Fire Trouble condition POWER will illuminate if the primary power is connected to the NX8 E control panel It will flash if the system has a low standby battery condition STAY will i...

Страница 20: ...he left will appear on the LCD screen TOP LINE OF DISPLAY disarmed areas to which this code has access BOTTOM LINE OF DISPLAY areas that are armed Table 8 1 List of Possible Conditions LCD DISPLAY If...

Страница 21: ...s ready to arm Press to exit the individual partition mode Silencing Alarms in the Multi Partition Mode If the keypad is sounding an alarm or the siren is running it can be silenced by entering a code...

Страница 22: ...ommunicate i e NX 580E NX 582E etc Expansion Over current A short circuit of an expansion device s power supply has occurred Expansion Power Trouble The main power to an expansion power supply is not...

Страница 23: ...3 4 5 6 7 8 1 192 193 194 195 196 197 198 199 2 200 201 202 203 204 205 206 207 3 208 209 210 211 212 213 214 215 4 216 217 218 219 220 221 222 223 5 224 225 226 227 228 229 230 231 6 232 233 234 235...

Страница 24: ...Sounder LCD KEYPAD DIMENSIONS 6 4 Wide 5 3 High 1 0 Deep SHIPPING WEIGHT 2 lbs COMPATIBLE NETWORX CONTROL PANELS NX 4 NX 6 NX 8 NX 8 CF NX 4V2 NX 6V2 NX 8V2 NX 8E CF Main 800 727 2339 Technical Suppo...

Отзывы: