LCD KEYPAD
22
Control
Fail to Comm.
The control attempted to communicate a message to the
Central Station, but was unsuccessful.
Control
Ground Fault
A short to ground has been detected on a control circuit.
Control
Loss of Time
Your system has lost total power and needs the clock reset.
Control
Power Trouble
The main power to your system is not on.
Control
Low Battery
The standby battery is low.
Expansion
Aux Comm
Fail
An auxiliary reporting device has failed to communicate, i.e.
NX-580E, NX-582E, etc.
Expansion
Over-current
A short circuit of an expansion device
=
s power supply has
occurred.
Expansion
Power Trouble
The main power to an expansion power supply is not on.
Expansion
Low Battery
An expansion power supply has a low battery.
Expansion
Box Tamper
A box containing an expansion device has been opened.
Expansion
RF Jammed
A radio receiver is being jammed.
Expansion
Trouble
An expansion device or keypad is not reporting to the control
panel.
Expansion
Siren trouble
An expansion device has detected some form of trouble on the
bell or siren circuit.
Zone
Tamper, Press
A zone is tampered. Press
to identify the tampered zone.