![GE NX-148E - Security NetworX LCD Keypad Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/ge/nx-148e-security-networx-lcd-keypad/nx-148e-security-networx-lcd-keypad_installation-and-setup_4082869017.webp)
LCD KEYPAD
17
[
new
user code]
Prompts for a user number. Repeat steps 3 and 4
if another user code needs to be programmed.
Keypad will beep 3 times if code is rejected.
#
while display is prompting
for a user number.
Exits and saves data.
7m. ASSIGNING AUTHORITY LEVEL
You must have authority to the partition you wish to add or remove from another person’s authority.
ACTION
RESULT
Prompts “Please Enter Your Code".
[master code]
Prompts for a user number.
[user code]
2-digit ID if NX-4, NX-4V2, NX-6,
NX-6V2, NX-8, NX-8V2, NX-8-CF
3-digit ID if NX-8E, NX-8E-CF (use
leading zeros!! (i.e.
for user 7)
Prompts through the following list of attributes.
Outputs used?
If NO…
If YES…
Master code?
Output 4 enable?
Sched arm only?
Output 3 enable?
Arm only?
Output 2 enable?
Reserved
Output 1 enable?
Open / Close Rprt?
Bypass
enable?
Arm
/
Disarm?
[partition number]
Default allows access to ALL partitions.
The first keypress will remove access to the
partition. To reestablish access, press the partition
number again.
Saves data. Prompts for next user code. Return to
step 3 to program another user code.
#
Exits this mode.
NOTE TO INSTALLER: Any master arm/disarm code can add or change a user code if the master
code has access to the same partitions as the code being added/changed. Consequently, when
programming the user codes for a partitioned system, leave at least one code access to all
partitions or you will not be able to add new users (can be "go to program code" if enabled in
location 43 of the control panel). If you desire the end user to be able to add new codes, you must
remove the partition authority from all blank codes.