5–8
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
SETTING PARAMETERS
CHAPTER 5: IP ADDRESSING
5.3
Setting Parameters
5.3.1
Setting Serial Port Parameters
To be compliant with IT or other policies the console parameters can be changed from the
CLI interface. This is best done by setting the IP address and then telnet over to the switch.
Once connected using telnet, the serial parameters can be changed. If you are using the
serial port, remember to set the VT-100 emulation software properties to match the new
settings.
The serial port parameters are modified using the
set serial
command with the
following syntax:
set serial [baud=<rate>] [data=<5|6|7|8>] [parity=<none|odd|even>] [stop=<1|1.5|2>]
[flowctrl=<none|xonxoff>]
Where
<rate>
= standard supported baud rates.
NOTE
Note
Changing these parameters through the serial port will cause loss of connectivity. The
terminal software parameters (e.g. HyperTerminal) will also have to be changed to match
the new settings.
To see the current settings of the serial port, use the
show serial
command to query the
serial port settings as illustrated below.
ML810#
show serial
Baud Rate: 38400
Data: 8
Parity: No Parity
Stop: 1
Flow Control: None
5.3.2
System Parameters
The system parameters can be queried and changed. To query the system parameters,
two commands are frequently used:
show sysconfig
and
show setup
. Usage for both
commands is illustrated below.
The following example lists system parameters using the
show setup
command. Most
parameters here cannot be changed.
ML810#
show setup
Version: ML810 build 3.3.0 March 19 2009 14:22:43
MAC Address: 00:20:06:27:0a:e0
IP Address: 3.94.247.41
Subnet Mask: 255.255.252.0
Gateway Address: 3.94.244.1
CLI Mode: Manager
System Name: ML810
System Description: 12 Port Modular Ethernet Switch