CHAPTER 8: ACCESS USING
INTRODUCTION TO
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
8–3
FIGURE 8–2: TACACS packet format
The portions of the TACACS packet are defined as follows:
•
Major Version
: The major version number.
•
Minor version
: The minor version number. This is intended to allow
revisions to the protocol while maintaining backwards compatibility.
•
Packet type
: Possible values are:
• TAC_PLUS_AUTHEN:= 0x01 (authentication)
TAC_PLUS_AUTHOR:= 0x02 (authorization)
TAC_PLUS_ACCT:= 0x03 (accounting)
•
Sequence number
: The sequence number of the current packet for the current
session.
•
Flags
: This field contains various flags in the form of bitmaps. The flag values
signify whether the packet is encrypted.
•
Session ID
: The ID for this session.
•
Length
: The total length of the packet body (not including the header).
754717A1.CDR
32 bits wide
4
4
8
8
8 bits
Major
Version
Minor
Version
Packet type
Sequence
number
Flags
Session ID
Length