7–12
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
CONFIGURING 802.1X WITH ENERVISTA SECURE WEB MANAGEMENT SOFTWARE
CHAPTER 7: ACCESS USING RADIUS
The
Tx Period
column represents the transmit period. This is the time (in seconds) the
authenticator waits to transmit another request for identification from the supplicant. The
values range from 1 to 65535 seconds, with a default of 30.
The backend or communication characteristics between the ML810 and the RADIUS Server
are defined through the
Configuration > Radius > Port > Access > Backend
menu item.
The
Supp Timeout
column represents the timeout the authenticator waits for the
supplicant to respond. The values range from 1 to 240 seconds, with a default of 30.
The
Server Timeout
column represents the timeout the authenticator waits for the
backend RADIUS server to respond. The values range from 1 to 240 seconds, with a default
of 30.
The
Max Request
column represents the maximum times the authenticator retransmits an
EAP request packet to the supplicant before it times out. Values are integers ranging from
1 to 10, with a default of 2.