7–10
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
CONFIGURING 802.1X WITH ENERVISTA SECURE WEB MANAGEMENT SOFTWARE
CHAPTER 7: ACCESS USING RADIUS
The following figure illustrates the editing of information for the RADIUS server. Note the
UDP port number can be left blank and the default port 1812 is used.
After configuring the server information, specific port information is configured.
Select the
Configuration > Radius > Port > Set
menu item to
configure the RADIUS characteristics of each port.
To edit the port settings, click on the edit icon (
).
Ensure that the port which has the RADIUS server is force authorized and asserted. For
other ports (user ports), it is best to leave the
Control
on auto and
Initialize
on de-asserted.