18–14
MULTILINK ML810 MANAGED EDGE SWITCH – INSTRUCTION MANUAL
MEMORY MAPPING
CHAPTER 18: MODBUS PROTOCOL
0240
Port 8: Number of broadcast frames
received
0 to
4294967295
1
F9
0
0242
Port 8: Number of multicast frames
received
0 to
4294967295
1
F9
0
0244
Port 8: Number of frames with CRC
error
0 to
4294967295
1
F9
0
0246
Port 8: Number of oversized frames
received
0 to
4294967295
1
F9
0
0248
Port 8: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1
F9
0
024A
Port 8: Number of jabber frames
received
0 to
4294967295
1
F9
0
024C
Port 8: Number of collisions occurred
0 to
4294967295
1
F9
0
024E
Port 8: Number of late collisions
occurred
0 to
4294967295
1
F9
0
0250
Port 8: Number of 64-byte frames
received/sent
0 to
4294967295
1
F9
0
0252
Port 8: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1
F9
0
0254
Port 8: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1
F9
0
0256
Port 8: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1
F9
0
0258
Port 8: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1
F9
0
025A
Port 8: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1
F9
0
025C
Port 8: Number of MAC error packets
0 to
4294967295
1
F9
0
025E
Port 8: Number of dropped received
packets
0 to
4294967295
1
F9
0
0260
Port 8: Number of multicast frames
sent
0 to
4294967295
1
F9
0
0262
Port 8: Number of broadcast frames
sent
0 to
4294967295
1
F9
0
0264
Port 8: Number of <64 byte fragments
with good CRC
0 to
4294967295
1
F9
0
0266
Port 9: Number of bytes received
0 to
4294967295
1
F9
0
0268
Port 9: Number of bytes sent
0 to
4294967295
1
F9
0
026A
Port 9: Number of frames received
0 to
4294967295
1
F9
0
026C
Port 9: Number of frames sent
0 to
4294967295
1
F9
0
026E
Port 9: Total bytes received
0 to
4294967295
1
F9
0
0270
Port 9: Total frames received
0 to
4294967295
1
F9
0
0272
Port 9: Number of broadcast frames
received
0 to
4294967295
1
F9
0
0274
Port 9: Number of multicast frames
received
0 to
4294967295
1
F9
0
0276
Port 9: Number of frames with CRC
error
0 to
4294967295
1
F9
0
Table 18–1: Modbus memory map (Sheet 11 of 33)
Address
Description
Range
Step
Format
Default
Содержание MultiLink ML810
Страница 36: ...1 26 MULTILINK ML810 MANAGED EDGE SWITCH INSTRUCTION MANUAL ML810 FIRMWARE UPDATES CHAPTER 1 SPECIFICATIONS ...
Страница 74: ...4 18 MULTILINK ML810 MANAGED EDGE SWITCH INSTRUCTION MANUAL TROUBLESHOOTING CHAPTER 4 OPERATION ...
Страница 328: ...18 38 MULTILINK ML810 MANAGED EDGE SWITCH INSTRUCTION MANUAL MEMORY MAPPING CHAPTER 18 MODBUS PROTOCOL ...