![GE MobileView 4 Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/ge/mobileview-4/mobileview-4_installation-manual_126706077.webp)
Chapter 5
Optional hardware installation
67
3. Mount the impact sensor.
4. Route the provided cable to the DVR. If you need to extend the cable, splice (solder
wires and heat shrink exposed wire) a three-conductor 18 AWG cable to the impact
sensor’s cable. Maximum cable length is 25 ft. (7.6 m).
5. See
and connect the impact sensor cable to the J13 back box connector as
follows:
•
Connect the red positive wire to J13.11.
•
Connect the black common wire to J13.10.
•
Connect the green or white input wire to J13.2.
•
Ensure that a jumper exists between J13.9 and J13.10.
•
Install a 10 kohm, 1/4 watt resistor between terminals J13.2 and J13.11.
Figure 52. Impact sensor wiring
MSS-7100-00-02
NC
Green or white
J13.2 - Digital input 2
10 kohm
resistor
Red
Black
J13.11 - 12V DC
J13.10 - GND
J13.9 - Digital input GND