26
Mercury Reference Manual
05-4446A01, Rev. C
2.7
STEP 6—CHECK FOR NORMAL
OPERATION
Once the data equipment is connected, you can check the transceiver for
normal operation.
Observe the LEDs on the top cover for the proper indications. In a nor-
mally operating system, you will see the following LED indications
within 45seconds of start-up:
•
PWR—
Lit continuously
•
LINK
—On, or blinking intermittently to indicate traffic flow
•
LAN
—On, or blinking intermittently to indicate traffic flow
Figure 2-4
shows a close-up view of the transceiver’s LED Indicator
panel.
Table 2-2
provides details on each LED function.
Invisible place holder
Figure 2-4. LED Indicator Panel
If the radio network seems to be operating properly based on observa-
tion of the unit’s LEDs, use the
PING
command to verify the link integ-
rity with the Access Point.
Table 2-2. Transceiver LED Functions
LED Label
Activity
Indication
PWR
ON
Primary power (DC) present
Blinking
Unit in “Alarmed” state
OFF
Primary power (DC) absent
LAN*
ON
LAN detected
Blinking
Data TX/RX
OFF
LAN not detected, or excessive
traffic present
COM1
(MGT System)
Blinking
Data TX/RX
OFF
No data activity
Содержание MDS Mercury Series
Страница 2: ......
Страница 10: ...2 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 28: ...20 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 36: ...28 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 140: ...132 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 142: ...134 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 156: ...148 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 168: ...160 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 184: ...176 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 194: ...I 10 Mercury Reference Manual 05 4446A01 Rev C ...
Страница 196: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www GEmds com 175 Science Parkway ...