Section 10 - Monitor Options
19
10. Monitor Options
PART
NUMBER
FULL
SCALE
RANGE
TRANSDUCER INPUT
ALARM RELAY
AGENCY
APPROVAL
3300/16
–
AXX
–
BXX
–
CXX
-
DXX
01 = 0 - 3 mil pp
02 = 0 - 5 mil pp
03 = 0 - 10 mil pp
04 = 0 - 15 mil pp
05 = 0 - 20 mil pp
11 = 0 - 100
µ
m pp
12 = 0 - 150
µ
m pp
13 = 0 - 200
µ
m pp
14 = 0 - 400
µ
m pp
15 = 0 - 500
µ
m pp
01 = 3300 8mm or
7200 5mm & 8mm or
3300XL 8mm
Proximitor
®
Sensor
200 mV/mil
02 = 3000 Proximitor
®
Sensor
200 mV/mil
03 = 7200 11mm
Proximitor
®
Sensor
100mV/mil
04 = 3300 HTPS 16mm
7200 14 mm
3300 XL 11 mm
Proximitor
®
Sensor
100 mV/mil
05 = 3300 RAM
Proximitor
®
Sensor
200 mV/mil
00 = NONE
01 = EPOXY SEALED
02 = HERMETICALLY
SEALED
03 = QUAD RELAY
00 = NOT REQUIRED
01 = CSA/NRTL
02 = BASEEFA
BARRIERS
USED
TRIP
MULTIPLY
EXX - FXX
00 = NO
01 =EXTERNAL *
02 = INTERNAL
00 = NONE
01 = 2X TRIP MULTIPLY
02 = 3X TRIP MULTIPLY
* External barriers should only be used with 3300 8mm or 7200 5mm & 8 mm or 3300XL
8mm Proximitor
®
Sensors and 3300 RAM Proximitor
®
Sensors. * See Calibration
Section
17.2
for more information.
NOTE: Verify that the transducer power supply level (-Vt) is appropriate for the
transducer being used. Both the Power Supply and the System Monitor must be
programmed to supply the correct voltage. The 3000 transducer requires a