![GDS Corp GDS-68XP Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/gds-corp/gds-68xp/gds-68xp_operation-and-maintenance-manual_571797034.webp)
GDS-68XP Operation & Maintenance Manual, Revision 3.4
Page 34
SENSOR REPLA CEMENT
If a sensor shows FAULT, does not respond to gas or can no longer be calibrated, it should be replaced.
Use type 10-98XX-Ryyyy sensors, where the XX is gas type (Fig. 3-1) and yyyy is range (25 = “0025”).
Step 1:
Turn off DC power.
Step 2:
Disconnect the sample inlet tube at
the sensor flow cell
Step 3:
Disconnect the sample exhaust tube at
the flow cell.
Step 4:
Unscrew the sensor flow cell and
sensor head cover
Step 5:
Pull straight down to remove the
existing sensor.
Step 6:
Compare the new sensor with the old
sensor and verify identical part numbers
Step 7:
Install the new sensor by aligning the
arrow on the sensor with the arrow on the
sensor head and pushing straight up.
Step 8:
Reassemble the sensor head cover and
flow cell and reattach the sample inlet and
outlet tubing.
Step 9:
Apply power, allow the sensor to
warm up for several hours.
Step 10:
Perform a complete calibration.
1
2
4
3
5
6
7
8