5. STOVE SET UP
5.1 Legs and front cover (See figure 3).
1.
Locate the four leg securing studs into
the four holes in the base of the body.
2.
Locate the four legs to the underside of
the casting body. There are two feet with
holes in the base. We recommend that
these be placed at the rear of the stove.
Note: If lying the stove on its top it is
advisable to remove the door before hand
as it is not designed to stay in place when
inverted.
3.
Place the front cover plate on top of the
front legs.
4.
Secure the legs and front cover to the
underside of the casting body using the
nuts and washers supplied. The bolts
should have the locking washer added first
followed by the flat washer. The legs are
fitted with height adjustment bolts that are to be used for levelling purposes only.
5.2 Deflector, diverter box and flue restrictor plate.
1. This appliance is supplied with a flue restrictor for use where the flue draught is
excessive. There may however, be certain circumstances where fitting the restrictor
causes the fire to fail the spillage test. In such cases the restrictor will have to be
removed. After
removal conduct the
spillage test again.
2. The deflector,
diverter box and flue
restrictor plate should
be assembled to the
stove as in figure 4.
The deflector must be
fitted first and is
secured in place
using the front bolt
that secures the flue
collar. Unscrew and
remove the nut and
washer from the front
bolt and position the
Page 12
©
GDC Group Ltd. 2015
INSTALLER GUIDE
Figure 4.
Figure 3.