8.2.4 Lighting the stove.
If closed
,
open the isolating ‘T’ connector valve.
Turn the ‘manual’ knob to the ON, full
counterclockwise
position.
Simultaneously press and hold the ‘OFF’ and
(large flame) buttons until a short acoustic
signal confirms the start sequence has begun;
release buttons. Continuing signals confirms
the ignition is in progress. There will be a slight
delay and several sparks should be see
n
between the electrode and pilot tip. Once pilot
ignition is confirmed there is main gas flow.
When pilot ignition is confirmed, the motor turns automatically to maximum flame
height.
8.2.5 Adjusting flame height.
When the burner is operating press the
(large flame) button to increase the
flame height and press the (small flame) to decrease the flame height. For fine
adjustment press the
/ button for approximately two seconds until an acoustic
signal is given, then release the button.
8.2.6 Adjusting to pilot only setting.
When the burner is operating press and hold the (small flame) until the burner
flame extinguishes. To turn the main burner on again simply press and hold the
(large flame) button.
8.2.7 Turning off.
To turn the fire off press the ‘OFF’ button.
Page 17
©
GDC Group Ltd. 2015
INSTALLER GUIDE
Figure 11. Controls
Main valve
knob
MAN (Manual)
Knob for manual
ignition