deflector as in figure 5, securing it
using the nut and washer. It
MUST be sealed against the top
of the stove casting. It is important
that it sits on top and between the
raised cast areas on the rear of
the stove body (See figure 5). The
flue spigot is screwed to the cast
collar and clamps the flue
restrictor plate in place (See figure
4).
5.3 Thermal switch.
The thermal switch should be fitted
to the inside of the diverter box as
in figure 6. Secure using the nut
and bolt supplied. Never modify
the fixing bracket and always
ensure that the switch is fitted
correctly. NEVER USE THE
STOVE IF THE THERMAL
SAFETY SWITCH HAS BEEN
REMOVED OR IF IT IS
DAMAGED IN ANY WAY.
6. BURNER AND SUPPLY LINE INSTALLATION
6.1 Burner installation.
1.
Unpack the burner module.
2.
Secure the control knob
assembly to the gas valve, the
screw tail should secure onto the
flat on the gas valve spindle
(manual model only).
3.
Secure the rear leg at the back
of the stove base using two No.4
x 10mm screws supplied (See
figure 7).
4.
Offer the burner module into
the stove and connect the
thermal switch leads to the tags mid way along the thermocouple.
Page 13
©
GDC Group Ltd. 2015
INSTALLER GUIDE
Figure 6.
Figure 5.
Figure 7.