handling the stove.
-
Always grip with the palm of the hand. Do not use the tips of fingers for support.
-
Always keep the stove as close to the body as possible. This will minimise the
cantilever action.
-
Use gloves to provide additional grip.
-
Always use assistance if required.
2. APPLIANCE DATA AND EFFICIENCY
2.1 General information.
*
When converting Manual using LPG kit
0595261.
Note:
- Converting from Natural gas (G20) to Propane (G31) is permitted ONLY on 944
MANUAL model together with the Coal ceramic set.
- If you have the 944 Manual with Log set conversion is NOT permitted.
- LPG conversion is also NOT permitted on the 944RC model (COAL or LOG).
The appliance data label is located on a plate at the base of the stove.
Page 7
©
GDC Group Ltd. 2015
INSTALLER GUIDE
Gas
Natural (G20)
Propane (G31) *
Inlet Pressure
20mbar
37mbar
Manual Input - Max. (Gross)
6.85kW (23,372 Btu/h)
6.7kW (22,860 Btu/h)
Manual Input - Min. (Gross)
2.3kW (7,850 Btu/h)
4.0kW (13,650 Btu/h)
RC Input - Max. (Gross)
6.85kW (23,372 Btu/h)
N/A
RC Input - Min. (Gross)
3.5kW (11,943 Btu/h)
N/A
Inlet Test Pressure (Cold)
20.0 ± 1.0mbar
(8.0 ± 0.4in w.g.)
37.0 ± 1.0mbar
(14.85 ± 0.4in w.g.)
Gas Connection
8mm pipe
8mm pipe
Burner Injector
Cat 82 - 072
Size 130
Pilot
Copreci Ref. O.D.S
21500/212
Copreci Ref. O.D.S
21500/212 Fitted with RBM
180 -02 injector
Manual Ignition
Integral piezo (Mounted on
gas valve)
Integral piezo (Mounted on
gas valve)
Remote Control Ignition
MERTIK GV60 battery
powered electronic remote
control
Conversion not permitted
on RC models
Aeration
See page 21
Non-adjustable