11. SERVICING
This product uses fuel effect pieces containing Refractory Ceramic Fibres
(RCF), which are man-made vitreous silicate fibres. Excessive exposure to
these materials may cause irritation to eyes, skin and respiratory tract.
Consequently, it is important to take care when handling these articles to
ensure that the release of dust is kept to a minimum. To ensure that the release
of fibres from these RCF articles is kept to a minimum, during installation and
servicing we recommend that you use a HEPA filtered vacuum to remove any
dust and soot accumulated in and around the stove before and after working on
the stove. When replacing these articles we recommend that the replaced items
are not broken up, but are sealed within a heavy duty polythene bag, clearly
labelled as RCF waste. RCF waste is classed as a stable, non-reactive
hazardous waste and may be disposed at a landfill licensed to accept such
waste. Protective clothing is not required when handling these articles, but we
recommend you follow the normal hygiene rules of not smoking, eating or
drinking in the work area and always wash your hands before eating or
drinking. This appliance does not contain any component manufactured from
asbestos or asbestos related products.
-
Always turn off the gas supply and allow to cool completely before commencing any
servicing.
-
Always test for gas soundness and spillage after servicing the appliance.
-
Check that the thermal switch is correctly located in the diverter box (See figure 6
on page 13).
-
Check that the appliance is clean and that no matter is blocking the burner or pilot
which may cause imperfect flames or prevent a correct electrode spark.
-
After servicing, make sure that the ceramic fuel effect pieces are replaced
correctly as described in the installer and owner guide supplied with the ceramic fuel
effect. The ceramic fuel effect guide may have been placed inside or attached to this
guide.
Checking the aeration setting of the burner.
(For LPG models refer to the conversion guide - 944 Manual
only).
-
The aeration shutter is factory set. It is important to ensure
that the aeration setting is correct. Check the aeration shutter
setting (See figure 13).
-
To adjust the aeration setting, loosen the two aeration shutter
screws, slide the aeration shutter to the position shown in
figure 13 and tighten the fixing screws.
Page 21
©
GDC Group Ltd. 2015
OWNER GUIDE
Figure 13. Aeration
shutter setting