manualshive.com logo in svg
background image

4

Fig. 1  Oscillation attenuation of timing belt

Fig. 2  U-507 relation between measured value and actual tension

2 

 

150 

 

100 

 

50 

 

 

 

100 

 

200 

 

300 

 

 

400 

 

500 

 

600 

 

100

200

300

400

500

600

50 

 

100 

 

150

Timing belt: 
3GT tooth shape x 3 mm wide

(V) 

 

0 

 

-2 

 

TIME A

LIN

80mS

.Measurement principle of U-507

When a belt tensed between pulleys is subjected to impact 
and vibrated, it oscillates first with an irregular waveform 
containing high frequency component and impact component 
as shown in figure 1, but soon oscillates with a intrinsic 
regular waveform.
U-507 tension meter was created in consideration of well-
known phenomenon described above, but the belt and wire 
attenuate in a very short time, and no simple device has 
existed which captures the cycle of such basic waveform.
However, a unique data processing method was developed 
which captures oscillation frequency making full use of 
microcomputer, and an attempt was successful to catch the 
cycle of such waveform rather easily.
This system detects oscillation waveform with a microphone, 
and the microcomputer processes the data and converts to 
characteristic frequency. "Horizontal oscillation of string" set 
on the tension meter described on the right in calculating the 
belt tension.

Here, the belt and the wire have a rigidity, which is different 
from the string, therefore U-507 measurement displayed is 
somewhat higher than the actual tension under the affected 
condition.
Therefore it is allowed to obtain correction factor by strict 
calibration test and incorporate it to the data input, thereby 
displaying more accurate tension.
An example of calibration result of U-507 measurement and 
actual tension is shown below:

Calculation formula  To = 4 x M x W x S

2

 x f

2

 x 10

-9

Where,

Therefore, it is required to input the length of span to be 
measured and the mass of belt (unit mass x width) by use of 
numeric key

3GT belt

Actual tension (N)

11. Actual tension (N)

U-507 measured value (N)

U-507 measured value (N)

Span length 86 mm

Span length 154 mm

 

 

Span length 365 mm

Span length 365 mm

 

 

[9 mm wide]

 

 

Standard installation 
tension of belt 
9 mm wide

Typical tension when 
stretching again

Typical 
installation 
tension

Standard installation 
tension of belt 
6 mm wide

[6 mm wide]

 

 

V riffed belt (3PK) belt

Span length 102 mm

Span length 201 mm

 

 

Span length 400 mm

 

 

To: Tension (N)

M: Unit mass (g/mm wide x m long)

W: Belt width or number of ribs (wires) (mm/R)

S: Measured span length (mm)

f: Horizontal characteristic frequency (Hz)

Содержание U-507

Страница 1: ...Input of span length Unit mass list of timing belt made by Gates Unitta Asia Unit mass list of V belt made by Gates List of standard installation tension of timing belt made by Gates Unitta Asia P P...

Страница 2: ...a wrong manne Caution This marking shows that possibility of injury is present and only physical damage is likely when the unit is used in a wrong mann The classified pictorial marking below shows des...

Страница 3: ...machine is stopped by turning off motor power supply or the lik The arm of flexible arm microphone is a universal pipe but must not be bent at an acute angle In addition do not bend the pipe within 20...

Страница 4: ...rement standby is displayed after the 3rd time and on In case of frequency mode The value changes greatly in every measurement The value responds sensitively to the noise around background noise other...

Страница 5: ...scillation of string set on the tension meter described on the right in calculating the belt tension Here the belt and the wire have a rigidity which is different from the string therefore U 507 measu...

Страница 6: ...off function to turn off power in about five minutes from the last measurement so if power is off during use press POWER button again 2 Explanation of each part of U 507 Main part Measurement sensor m...

Страница 7: ...es dual display with tension and frequency However CAT display is available only when inputting from preinstalled data Displays only for timing belt Displayed CAT value for tension and frequency are s...

Страница 8: ...returns to the first and input of data is requested again 0 button PUSH 2 button PUSH 5 button PUSH 4 button PUSH W mm R Allowable input capacity 000 1 999 9 mm W mm R W mm R W mm R W mm R Input the s...

Страница 9: ...corresponds to one piece for V belt and wire and one rib for V ribbed belt Note Unit mass of U 507 U 505 and U 305 is 10 times the input of conventional type U 303 since the input unit has been chang...

Страница 10: ...scription of MASS button on page 5 and 6 for selecting Input a value manually by use of unit mass list on the next page as for special pitch and special belt which are not described below List of prei...

Страница 11: ...27 0 0 95 25 7 11M 56 0 0 93 52 1 J section 9 0 0 95 8 6 L section 32 0 0 95 30 4 PK section 21 0 0 95 20 0 A 120 0 0 86 103 2 B 200 0 0 83 166 0 C 360 0 0 83 298 8 D 660 0 0 81 534 6 E 1020 0 0 72 7...

Страница 12: ...T N N MIN MAX MIN MAX 210 155 125 260 310 410 520 625 730 830 440 325 260 545 650 860 1090 1310 1530 1740 530 795 1060 1325 1590 1855 2650 3050 2120 3445 1110 1670 2230 2780 3340 3895 5565 6405 4450 7...

Страница 13: ...e and turn it several times to make the machine familiar and measure the tension of 2 spans on belt tension side and loosening side and take the average When tension of 2 spans is different more than...

Страница 14: ...10 to 5000 Hz and measure in the same way as measurement of tension which enables certification easily Tension meter certifying device U 305 OS1 is also in market If you contact our sales department w...

Страница 15: ......

Страница 16: ...HEAD OFFICE 4 26 SAKURAGAWA 4 CHOME NANIWA KU OSAKA 556 0022 JAPAN TEL 06 6563 1284 FAX 06 6563 1285 July 15 2005 2 000 parts D...