. Overview, note, and checking item in defective measurement
The sonic belt tension meter (U-507) enables non-contact,
simple, and accurate measurement of installation tension
which is greatly related to belt function by analyzing sonic
wave.
Sonic wave is generated by flipping the belt span with the
belt standing still, and it is captured by the sensor and
processed by high performance computer, and belt tension is
displayed in digital mode.
■
Overview
■
Overview & checked item in measurement malfunction (when unsuccessful)
[Measurement mode is not established or data fluctuates significantly.]
Item
*
If measurement is still unsuccessful after retrial of the procedure above, contact us or the dealer you purchased this unit.
Phenomenon
Estimated cause (Assumed causes)
Checked item
"Error" is displayed
or Measurement
mode is not
established, or LED
(red) is on.
Output fluctuates
greatly.
●
Tension value
doesn
,
t come out
dispite a few of trials.
Otherwise, only
"Measurement
standby" is displayed
after the 3rd time and
on.
(In case of frequency
mode)
●
The value
changes greatly in
every measurement.
●
The value
responds sensitively
to the noise around
(background noise)
other than measured
value.
●
"0" is entered to the entry
parameters (unit mass, width, and
span).
●
Tension value has 6 digits or
more.
●
Measurement frequency range is
incorrect.
●
Measurement frequency exceeds
5000 Hz.
●
Exhaustion of battery
●
Microphone is in contact with the
belt for a moment during
measurement.
●
Automatic gain adjustment is
insufficient.
●
Check the detail of entry item.
(Enter an appropriate value to the
item that "0" is input.)
●
Tension is not measured although
frequency is displayed.
●
Change of measurement
frequency range (switching LOW
and STANDARD, switching
STANDARD and HIGH)
●
Check whether measurement
frequency is in excess of 5000 Hz or
not.
●
Indication of battery life
(When the battery display is as
shown on the right:
)
●
Try measurement again at a
appropriate distance where
microphone is not in contact.
●
Turn off power once at a
measurement place, and turn on
again.
(Turn on power with microphone
installed, and press "MEASURE"
button over one second later.)