Gates Unitta Asia U-507 Скачать руководство пользователя страница 9

8

.Input procedure of data

-

.Input of unit mass

[See table-1, table-2, and table-3.]

● 

Timing flat belt

Input the mass per width (mm) x length (m) in "g/mm W x m L" 
for unit mass.
Data of capacity can be input by four significant digits, i.e. three 
digits of integer and one digit below decimal point from 000.1 up 
to 999.9 g/mm W x m L.

 

● 

Timing V-belt

      (Input of belt unit mass from preinstalled data)

  

When "MASS" button is held down (longer than one second), 
belt type is displayed on LCD. Scroll the display with UP button 
("2") or DOWN button ("8") until the letter of desired belt type is 
highlighted. Then press "MEASURE" button for determining.

 

 

V, V-ribbed belt and wire

Input the mass per meter of length in "g/m length" for unit mass. 
Data of capacity can be input by four significant digits, i.e. three 
digits of integer and one digit below decimal point from 000.1 up 
to 999.9 g/m L. Unit mass corresponds to one piece for V-belt 
and wire, and one rib for V-ribbed belt.

 

Note) Unit mass of U-507, U-505, and U-305 is 10 times the 
input of conventional type U-303 since the input unit has been 
changed.
Therefore, when a value is input in conventional unit mass 
(g/cm2), measured tension is displayed in 1/10. (Display of 
measured frequency is not changed.)

-

.Input of belt width or 

       the number of belts (ribs)

● 

Timing flat belt

Data of belt width can be input by four significant digits, i.e. 
three digits of integer and one digit below decimal point in 
millimeters from 000.1 to 999.9 mm.

 

 

● 

V, V-ribbed belt and wire

 

Input one (piece) of V-belt and wire.
Input the number of ribs of V-ribbed belt.

 

-

. Input of span length

Span length is a distance between contacts with pulley, and can 
be calculated by the following equation accurately. Alternatively, 
measure the distance between pulley contacts with a measuring 
tape for facilitation.

 

where,
s: Span length (mm)
C: Distance between axes (mm)
Dp: Large pulley pitch outer diameter (mm)
dp: Small pulley pitch outer diameter (mm)

S= C − 

(Dp−dp) 

4

2

2

Содержание U-507

Страница 1: ...Input of span length Unit mass list of timing belt made by Gates Unitta Asia Unit mass list of V belt made by Gates List of standard installation tension of timing belt made by Gates Unitta Asia P P...

Страница 2: ...a wrong manne Caution This marking shows that possibility of injury is present and only physical damage is likely when the unit is used in a wrong mann The classified pictorial marking below shows des...

Страница 3: ...machine is stopped by turning off motor power supply or the lik The arm of flexible arm microphone is a universal pipe but must not be bent at an acute angle In addition do not bend the pipe within 20...

Страница 4: ...rement standby is displayed after the 3rd time and on In case of frequency mode The value changes greatly in every measurement The value responds sensitively to the noise around background noise other...

Страница 5: ...scillation of string set on the tension meter described on the right in calculating the belt tension Here the belt and the wire have a rigidity which is different from the string therefore U 507 measu...

Страница 6: ...off function to turn off power in about five minutes from the last measurement so if power is off during use press POWER button again 2 Explanation of each part of U 507 Main part Measurement sensor m...

Страница 7: ...es dual display with tension and frequency However CAT display is available only when inputting from preinstalled data Displays only for timing belt Displayed CAT value for tension and frequency are s...

Страница 8: ...returns to the first and input of data is requested again 0 button PUSH 2 button PUSH 5 button PUSH 4 button PUSH W mm R Allowable input capacity 000 1 999 9 mm W mm R W mm R W mm R W mm R Input the s...

Страница 9: ...corresponds to one piece for V belt and wire and one rib for V ribbed belt Note Unit mass of U 507 U 505 and U 305 is 10 times the input of conventional type U 303 since the input unit has been chang...

Страница 10: ...scription of MASS button on page 5 and 6 for selecting Input a value manually by use of unit mass list on the next page as for special pitch and special belt which are not described below List of prei...

Страница 11: ...27 0 0 95 25 7 11M 56 0 0 93 52 1 J section 9 0 0 95 8 6 L section 32 0 0 95 30 4 PK section 21 0 0 95 20 0 A 120 0 0 86 103 2 B 200 0 0 83 166 0 C 360 0 0 83 298 8 D 660 0 0 81 534 6 E 1020 0 0 72 7...

Страница 12: ...T N N MIN MAX MIN MAX 210 155 125 260 310 410 520 625 730 830 440 325 260 545 650 860 1090 1310 1530 1740 530 795 1060 1325 1590 1855 2650 3050 2120 3445 1110 1670 2230 2780 3340 3895 5565 6405 4450 7...

Страница 13: ...e and turn it several times to make the machine familiar and measure the tension of 2 spans on belt tension side and loosening side and take the average When tension of 2 spans is different more than...

Страница 14: ...10 to 5000 Hz and measure in the same way as measurement of tension which enables certification easily Tension meter certifying device U 305 OS1 is also in market If you contact our sales department w...

Страница 15: ......

Страница 16: ...HEAD OFFICE 4 26 SAKURAGAWA 4 CHOME NANIWA KU OSAKA 556 0022 JAPAN TEL 06 6563 1284 FAX 06 6563 1285 July 15 2005 2 000 parts D...

Отзывы: