background image

9

1

2

3

 List of timing belt unit mass specified as standard configuration

Timing belt

HTD belt

GT belt

4 Polychain GT2 belt

5 Carryflex timing belt

6 Non standard pitch belt

7 Urethane belt

Tooth type

Pitch

mm

MXL

2.032

1.2

XXL

(50) 

3.175

1.4

XL

5.080

2.1

DXL

5.080

1.9

L

9.525

3.1

DL

9.525

3.3

H

12.700

3.8

DH

12.700

4.4

XH

22.225

11.1

XXH

31.750

14.8

Unit mass

g/mm with

×

m length

Tooth type

Pitch

mm

Unit mass

g/mm with

×

m length

Tooth type

Pitch

mm

Unit mass

g/mm with

×

m length

Tooth type

Pitch

mm

Unit mass

g/mm with

×

m length

Tooth type

Pitch

mm

Unit mass

g/mm with

×

m length

Tooth type

Pitch

mm

Unit mass

g/mm with

×

m length

Tooth type

Pitch

mm

Unit mass

g/mm with

×

m length

3M-HTD

3.000

2.4

D3M-HTD

3.000

2.3

5M-HTD

5.000

3.8

D5M-HTD

5.000

4.2

8M-HTD

8.000

6.1

D8M-HTD

8.000

6.3

EV14M

14.000

8.7

14M-HTD

14.000

10.0

D14M-HTD

14.000

11.9

20M-HTD

20.000

12.8

8M-GT

8.000 

 

4.7

14M-GT

14.000

8.0

XL

5.080

1.7

L

9.525

2.6

C8YU

8.000

5.2

H

12.700

3.4

T5

5.000

1.8

T10

10.000

3.6

101

1.5875

1.0

102

2.0320

1.3

103

2.1167

1.3

104

2.8222

1.0

111

1.4111

1.1

109

2.1167

1.1

181

2.8222

0.9

25

6.3500

1.7

9109

15.4473

3.0

UMXL

2.032

0.9

UXL

5.080

1.6

1.5GT

1.500

0.9

2GT

2.000

1.3

3GT

3.000

2.5

D3GT

3.000

2.5

5GT

5.000

4.0

D5GT

5.000

4.3

EV8YU

8.000

5.1

D8YU

8.000

5.4

8YU

8.000

5.2

See the description of MASS button on page 5 and 6 for selecting. Input a value manually by use of unit mass list on the next 
page as for special pitch and special belt which are not described below.

.List of preinstalled belt type unit mass

 Table-2: Unit mass only for U-507/505 and U-305

Data of unit mass can be input by four significant digits, i.e. three digits of integer and one digit below decimal point in g/mm W x 
m L from 0.1 to 999.9 g/mm W x m L.

.Unit mass list of timing belt made by Gates Unitta Asia

Note) Input a value 10 times the unit mass list value (g/cm) 
used for present U-303.

MXL 

XL 

DXL 

DL 

DH 

XH 

XXH 

 

1.2 

2.1 

1.9 

3.1 

3.3 

3.8 

4.4 

11.1 

14.8 

 

3M 

D3M 

5M 

D5M 

8M 

D8M 

14M 

D14M 

20M

2.4 

2.3 

3.8 

4.2 

6.1 

6.3 

10.0 

11.9 

12.8

1.5GT 

2GT 

3GT 

D3GT 

5GT 

D5GT 

8YU 

D8YU 

8MGT 

 

0.9 

1.3 

2.5 

2.5 

4.0 

4.3 

5.2 

5.4 

4.7

14MGT 

EV8M 

EV14M

8.0 

5.1 

8.7

3VX 

5VX 

8VX 

J(V) 

K(V) 

L(V) 

A(V) 

B(V) 

C(V) 

 

 

59.8 

165.6 

525.6 

8.6 

20.0 

30.4 

103.2 

166 

298.8 

 

D(V) 

E(V) 

3VXPB 

5VXPB 

5MPF 

7MPF 

11MRF

534.6 

734.4 

75.7 

210.9 

10.5 

25.7 

52.1

Display

Timing belt (Standard construction)

V belt

Unit mass Display Unit mass Display Unit mass Display Unit mass

Display

Unit mass

Display

Unit mass

■ 

Table-1: List of unit mass of toothed belt and V-belt

Display

Belt type

Display

Belt type

Display

Belt type

Display

Belt type

8MGT 
14MGT

Polychain GT2   8M 
Polychain GT2 14M

3VXPB 
5VXPB

3VX Powerd band 
5VX Powerd band 
 

5MPF 
7MPF

Polyflex 5M 
Polyflex 7M

11MRF

Polyflex 11M

(unit:g/mm width x m length)

unit mass: Mass per meter length of one rib(g/m length)

Содержание U-507

Страница 1: ...Input of span length Unit mass list of timing belt made by Gates Unitta Asia Unit mass list of V belt made by Gates List of standard installation tension of timing belt made by Gates Unitta Asia P P...

Страница 2: ...a wrong manne Caution This marking shows that possibility of injury is present and only physical damage is likely when the unit is used in a wrong mann The classified pictorial marking below shows des...

Страница 3: ...machine is stopped by turning off motor power supply or the lik The arm of flexible arm microphone is a universal pipe but must not be bent at an acute angle In addition do not bend the pipe within 20...

Страница 4: ...rement standby is displayed after the 3rd time and on In case of frequency mode The value changes greatly in every measurement The value responds sensitively to the noise around background noise other...

Страница 5: ...scillation of string set on the tension meter described on the right in calculating the belt tension Here the belt and the wire have a rigidity which is different from the string therefore U 507 measu...

Страница 6: ...off function to turn off power in about five minutes from the last measurement so if power is off during use press POWER button again 2 Explanation of each part of U 507 Main part Measurement sensor m...

Страница 7: ...es dual display with tension and frequency However CAT display is available only when inputting from preinstalled data Displays only for timing belt Displayed CAT value for tension and frequency are s...

Страница 8: ...returns to the first and input of data is requested again 0 button PUSH 2 button PUSH 5 button PUSH 4 button PUSH W mm R Allowable input capacity 000 1 999 9 mm W mm R W mm R W mm R W mm R Input the s...

Страница 9: ...corresponds to one piece for V belt and wire and one rib for V ribbed belt Note Unit mass of U 507 U 505 and U 305 is 10 times the input of conventional type U 303 since the input unit has been chang...

Страница 10: ...scription of MASS button on page 5 and 6 for selecting Input a value manually by use of unit mass list on the next page as for special pitch and special belt which are not described below List of prei...

Страница 11: ...27 0 0 95 25 7 11M 56 0 0 93 52 1 J section 9 0 0 95 8 6 L section 32 0 0 95 30 4 PK section 21 0 0 95 20 0 A 120 0 0 86 103 2 B 200 0 0 83 166 0 C 360 0 0 83 298 8 D 660 0 0 81 534 6 E 1020 0 0 72 7...

Страница 12: ...T N N MIN MAX MIN MAX 210 155 125 260 310 410 520 625 730 830 440 325 260 545 650 860 1090 1310 1530 1740 530 795 1060 1325 1590 1855 2650 3050 2120 3445 1110 1670 2230 2780 3340 3895 5565 6405 4450 7...

Страница 13: ...e and turn it several times to make the machine familiar and measure the tension of 2 spans on belt tension side and loosening side and take the average When tension of 2 spans is different more than...

Страница 14: ...10 to 5000 Hz and measure in the same way as measurement of tension which enables certification easily Tension meter certifying device U 305 OS1 is also in market If you contact our sales department w...

Страница 15: ......

Страница 16: ...HEAD OFFICE 4 26 SAKURAGAWA 4 CHOME NANIWA KU OSAKA 556 0022 JAPAN TEL 06 6563 1284 FAX 06 6563 1285 July 15 2005 2 000 parts D...

Отзывы: