DISPLAY
(G)
Backlight display automatically turn off without operation.
Push any button to turn it on again.
Screen displays information / settings below:
-
Operation modes
-
Temperatures
-
Parameters
-
Faults / errors
HEATING MODE BUTTON
(H)
Used for to choose and select 4 different heating modes.
DHW MODE BUTTON
(I)
Used for to turn on or off the DHW mode.
NAVIGATION AND ADJUSTMENT KNOB
(B)
Changes comfort temperature setting. Additionally it also
used for;
increase / decrease temperatures,
choose and select sub menus,
Change the settings.
OK BUTTON
(C)
Used for to apply selected value or setting. In the parameters
section this button is used for the further menu options.
HEATING MODE SELECTION :
Press the appropriate button to select between different
heating modes:
CANCEL BUTTON – ESC
(A)
Used for to cancel the settings and return to upper menu
section.
MANUAL CONTROL BUTTON
(D)
Used for to run to boiler manually. During the manual
operation all pumps will be ran, but mixing valves wouldn’t
be operated. Burner temperature will be held at adjusted
temperature while the commissioning. Pushing to this button
more than 3sec will be opareted the air relief function. During
this function burner will held into standby mode, pumps will
be energised periodically, mixing valves ran into middle
position. This function will be turned off automatically after
the cycle.
FLUE FUNCTION
(E)
Used for flue gas emission measuring. During this function
boiler will be operated according to maximum adjusted
temperature until it reach the exact value. Then this function
will be turned off automatically.
INFO BUTTON
(F)
Used for the display boiler information such as temperatures,
operating modes, error codes etc.
RESET BUTTON
(J)
Used for to reset any fault and error which caused to stop the
boiler.
Auto
: Boiler will be operated according to
adjusted time program.
Comfort Temperature
: Boiler will be
operated according to adjusted comfort
temperature permanently.
Reduced Temperature
: Boiler will be
operated according to adjusted reduced
temperature permanently.
Standby
: Heating will be turned off, but
frost protection still activated unless the
power supply is disconnected.
DHW MODE SEELECTION :
When the corresponding button is used,
the boiler is switched on to operate
synchronously with the units that
produce hot water (DHW tank, plate heat
exchanger, etc.). This function can be
switched off or on.
Pressing the button once will be activate
the boiler to heat the DHW tank. Pressing
it again disables DHW tank heating.
Pressing the button for 3 seconds
activates the Quick Water Heating Mode
for faster hot water production.
32