6.5
MAIN FUNCTIONS
Button
Action
Procedure
Display / Function
Actuate rotary knob left/right
Comfort setpoint with blinking temperature
Turn rotary knob Confirm with OK button Blinking temperature in 0,5 °C steps from 10 to 30 °C
or wait 5 sec.
Comfort setpoint saved
or press
Comfort setpoint cancelled
- after 3 sec. Main menu appears
Set room temperature for
Zone 2 independent from zone 1
Choose heating zone
zone 1 or zone 2
Actuate rotary knob left/right
Heating zone is chosen
Confirm with OK button
Blinking temperature in 0,5 °C steps from 10 to 30 °C
Actuate rotary knob left/right
Confirm with OK button
or wait 5 sec.
Comfort setpoint saved
or press
Comfort setpoint cancelled
- after 3 sec. Main menu appears
Switch on /off DHW operation
Press button
DHW mode on / off
(see indication below DHW symbol)
- On: DHW mode by time programm
- Off: no DHW operation
- Safety functions activated
Factory setting
Automatic mode on, with:
- Heating by time programm
- Temperature setpoint by heating programm
- Safety functions activated
- Summer/Winter automatic switching activated
- ECO-functions activated
(see indication below operation symbol)
Press button 1x
Continuous COMFORT heating on, with:
- Heating without time programm by comfort setpoint
- Safety functions activated
Press button 1x again
Continuous REDUCED heating on, with:
- Heating without time programm by reduced setpoint
- Safety functions activated
- Summer/Winter automatic switching activated
- ECO-functions activated
Press button 1x again
Safety mode on, with:
- Heating off
- Temperature by frost protection
- Safety functions activated
Controller Stop Mode
Press button > 3 sec.
304: Controller Stopp mode insert setpoint
Press button > 3 sec. again
after 3 sec. Main menu appears
Press button 1x
INFO Segment displayed
Press button 1x again
- Status Boiler - room temperature
Press button 1x again
- room temperature minimum
…..
- Status DHW - room temperature maximum
- Status zone 1 - outside temperature
Info display
- Status zone 2 - outside temperature minimum
Time / Date - DHW temperature 1
- Error indication - Boiler temperature
- Maintenance indication - Flow temperature
(Info display depends on configuration)
Press button 1x
Back to main menu; INFO Segment disappears
Operation by manual
Press button 1x
Manual mode on
(spanner symbol appears)
setpoint
- Haeting by fixed setpoint
Change factory setting
Press button
(factory setting = 60 °C)
boiler temperature
Press button
301: Manual mode insert setpoint?
Turn rotary knob -/+
blinking temperature
Press button
set value
Press button
Status boiler
Press button
Manual mode off (spanner symbol disappears)
Deaeration
Press button > 3 sec.
312: Deaeration on
Press button > 3 sec. again
Deaeration off
Activate chimney sweeper
Press button (< 3 sec.)
Chimney sweeper mode on
mode
Press button again (< 3 sec.)
Chimney sweeper mode off
Temporary reduction of
Press button
Heating by reduced setpoint
reduced temperature on QAA75
Press button again
Heating by comfort setpoint
Reset button
Press button (< 3 sec.)
Boiler manually blocked, no release
Press button again > 3 sec.
Boiler released, Alarm symbol disappears
RESET
Change heating operation
mode
Zone 1 and zone 2
Set room temperature
35
Содержание ALUBOX X-treme Series
Страница 24: ...23...
Страница 25: ...24...
Страница 26: ...25...
Страница 27: ...OCI 351 Modbus Module 26...
Страница 46: ...15 TROUBLESHOOTING 45...