33
ADJUSTING THE ROOM TEMPERATURE:
The temperature (comfort value) of the room which is heated
by the heating circuit-1 is set by the Navigation Button. The
boiler will be activated and keep the room temperature
constant to the set temperature.
To adjust;
Turn the Navigation Knob in any direction
Set the desired room temperature and press OK. (Factory
setting is 20°C)
ADJUSTING OTHER HEATING CIRCUITS:
If there is more than one heating circuit in the system, the
comfort temperature can be set separately for each circuit.
To adjust;
Press OK
Turn the Navigation Knob to select Heating circuit-2 and press
OK
Adjust the desired room temperature and press OK
Press ESC button to return upper menu and adjust other
heating circuits
REDUCED TEMPERATURE:
A temperature limit for the room temperature. When the room
temperature falls below the set temperature, the boiler will be
activated and keep the room temperature constant. (Factory
setting is 10 °C)
To adjust;
Press OK
Turn the Navigation Knob and select Heating circuit-1 by pressing
OK
Turn the navigation Knob and select Heating circuit-1 Reduced
setting temperature by pressing OK
Adjust the desired Reduced setting temperature and press OK.
Press ESC button to return upper menu and adjust other heating
circuits