MDE-5411A ForeHB Islander Prime Installation Manual · October 2018
Page 19
3.7 Technical Specifications and Standards
System Overview
3.7 Technical Specifications and Standards
The following details the technical specifications, as well as the communication and security
standards for the Islander Prime.
3.7.1 Islander Prime Technical Specifications
The following details the physical, electrical, and environmental specifications of the Islander
Prime (see
Table 2: Islander Prime Technical Specifications
Parameter
Value
Dimensions (H x W x D)
Standard:
158 x 30 x 29 cm | 62.2-inch x 11.8-inch x 29.2-inch in.
ADA accessible
: 128 x 30 x 29 cm | 50-inch x 11.8-inch x 29.2-inch.
Supply Voltage
100 - 240 VAC
Power Consumption
2A max
Operating Temperature
Without Printer
: -40° to +65°C | -40° to +149°F
With Printer
: -40° to +50°C | -40° to +122°F
With Barcorde
: -30° to +60°C | -22° to +140°F
Storage Temperature
-40° to +70°C | -40° to +158°F
Humidity
80% Non-condensing
Communication Interface
• RS-485
• RS-232
• RS-422
• LAN
Pump Communication Interface
• RS-485
• RS-422
• Current Loop
• MPI-C
• Tokheim
Wireless Communication
Optional wireless communication IEEE802.15.4 with proprietary mesh
network (License)
Pump Control Maximum Current
(4 Solid State Relay Channels)
Maximum of 380mA current for each channel, either for driving the external
relay of the pump motor or for driving the solenoid valve
Power supply output voltage to Pulser
unit
12 VDC +/- 20% 50mA
Power Supply Maximum Output
Current
8 A max
Pulser Input High level Voltage
9 to 15 VDC
Pulser Input Low level sink current
(@15V)
3mA max.
In use “On” level (Input)
100 – 240 VAC, 50/60 Hz, 5mA
In use “Off” level (Input)
0 to 10 VAC
Certifications
ETL, CE, FCC, cETLus
Optional Accessories
• Printer
• EMV Card Reader and Payment
• Insert Card Reader
• HID Card Reader
• Barcode Reader
• ADA (Americans with Disabilities Act) Pedestal
• Stainless Steel Pedestal
Содержание Islander Prime