Installation
5.5 Installing Communication Interfaces
Page 60
MDE-5411A ForeHB Islander Prime Installation Manual · October 2018
5.5.3.5 Fuses
Mechanical pumps are supplied with power via fuses located below the pump slots
(see
,
,
Figure 48: MPI-C Fuses Diagram
Table 12:
In Use
Pump
INUSE1_A
INUSE2_A
INUSE3_A
INUSE4_A
LINE1
LINE2
LINE3
LINE4
INUSE1_B
INUSE2_B
INUSE3_B
INUSE4_B
LOAD1
LOAD2
LOAD3
LOAD4
MPI-C Fuses Slot #1- In Use/Pump
Table 13:
In Use
Pump
LINE1
LINE2
LINE3
LINE4
INUSE1_A
INUSE2_A INUSE3_A
INUSE4_A
LOAD1
LOAD2
LOAD3
LOAD4
INUSE1_B
INUSE2_B INUSE3_B
INUSE4_B
MPI-C Fuses Slot #2 - Pump/In Use
5.5.4 Pulser Connections
The following describes the required wiring connections between the pulser in the mechanical
pump and Islander Prime. The system can accept many types of pulsers; contact Gasboy for
more information. There are two types of pulser:
• Electronic pulser
• Mechanical pulser
Connect Islander Prime to the pulser in accordance to its characteristics.
Note: Pulsers should be installed in accordance with the pulser manufacturer's instructions.
Some pulsers do not have a barrier; in that case, you must add a pulser barrier.
Barriers are not provided with Islander Prime.