LAN CommVerter Setup
6.3 Setup
Page 74
MDE-5411A ForeHB Islander Prime Installation Manual · October 2018
Table 20: OrIC Config Channels Fields
Field
Description
Host
TCP/IP Port
Host TCP/IP Port
Device Name
Device Name (Ideally should reflect the corresponding destination, i.e. “CL” for Current Loop
destinations)
Destination
OrIC Number
Channel number between 1-12 (up to 4 per PI)
Comm. Type
Communication protocol for the interface Current Loop
• RS-232
• RS-422
• RS-485
• Tokheim
• MPI-Primary
• MPI-Secondary
RS-232 and RS-422 channels are configured on the same PI- channels 1/2 are RS-232 and
channels 3/4 are RS-422
MPI-Primary and -Secondary are used for mechanical PIs, MPI-Secondary is used for channels
3/4 in configurations that enable 4 MPI-C channels.
Baud Rate
Communication Interface details
Data Bits
Parity
Stop Bits
RS-485 Echo
(RS-485 channels only)
Current Select
(Current Loop channels only) Type of current used by the channel
Frame Timeout Longest pause in milliseconds between received bits before destination interface interprets the
pause as the end of one message, and interprets further transmissions as a new message (0 = 4
bytes of silence).
No Data
Timeout
The controller checks communication at regular intervals. If no communication is detected within
the timeout interval, the channel will automatically reset. If set to 0, the channel will not reset.
Note: If the channel configuration is not displayed properly after saving all changes and resetting the device, clear
your browser cache and reload the page.